Parts and Functions

 

 

Indoor Unit

 

 

 

Remote controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

8

11

12

9. LOCK display

 

 

 

1

13

 

 

 

10

10. SWING display

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

9

15

11. Mode display

 

 

 

 

 

8

16

Operation mode AUTO COOL

DRY

FAN

HEAT

 

 

17

 

 

ON/OFF

Remote controller

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

3

6

FAN 5

18

12.

TEMP display

 

 

13. SIGNAL SENDING

 

14.

TIMER OFF display

4

6

7

MODE

SWING

POWER/SOFT

TIMER

15. TIMER ON display

1916. CLOCK display

20

17. SLEEP display

 

5

4

21

18. POWER ON/OFF button

1

Inlet

6

Display board

2

Inlet grille

7

Emergency Switch

3

Outlet

8

Air Purifying Filter

4

Vertical blade

 

(inside)

 

 

(adjust left and right air flow)

5Horizontal flap

3CLOCK

LIGHT

2 SET SLEEP

1

LOCK RESET

22

19. SWING button

2320. HOUR / POWER/SOFT button

24

Used to set clock and timer setting. Press this button at any time except for setting the remote control time and setting timedisplay changes as follows:

BLANK

POWER SOFT

(adjust up and down air flow.

Don't adjust it manually)

Please be subject to the actual produce purchased the above picture is just from your reference

Outdoor Unit

1. LOCK button

Used to lock buttons and LCD display.

2.SET / LIGHT button

3.CLOCK button

4.MODE button

5.TEMP.SETTING button

6.FAN button

7.HEALTH display

8.FAN SPEED display

21. TIMER button

Used to set correct time.

22.HOUR button

23.SLEEP button

24.RESET button

When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.

AUTO LO MED HI

 

4

OUTLET

CONNECTING PIPING AND ELECTRICAL WIRING

INLET

 DRAIN HOSE

Please be subject to the actual produce purchased the above picture is just from your reference

Clock set

Press CLOCK button, "AM" or "PM" flashes.

Press or to set correct time. Each press will increase or decrease 1min. If the button is kept pressed,time will change quickly. After time setting is confirmed,press SET,

"AM "and "PM" stop flashing,while clock starts working.

POWER/SOFT

TIMER

CLOCK

LIGHT

SET SLEEP

LOCK RESET

Loading of the battery

 

1Remove the battery cover;



2 Load the batteries as illustrated.

 

2 R-03 batteries, resetting key



(cylinder);

 

3 Be sure that the loading

4



is in line with the" + "/"-";

 

Load the battery,then put on the cover again.

Note:

The distance between the signal transmission head and the rece- iver hole should be within 7m without any obstacle as well.

When electronic-started type fluorescent lamp or change- over type fluorescent lamp or wireless telephone is installed in the room, the recei ver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.

Full display or unclear display during operation indicates the batteries have been used up.Please change batteries.

If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.

Hint:

Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.

2

Page 2
Image 2
Haier HSU-24HEK03/R2, 0010530627 operation manual Parts and Functions

HSU-24HEK03/R2, 0010530627 specifications

The Haier HSU-24HEK03/R2 is a cutting-edge air conditioning unit that combines efficiency, advanced technology, and user-friendly features, making it a popular choice for residential and commercial spaces. Designed to provide superior cooling and heating performance, this model is an excellent addition to any indoor environment, ensuring comfort year-round.

One of the standout features of the HSU-24HEK03/R2 is its impressive cooling capacity of 24,000 BTU, which makes it suitable for larger rooms or open-concept spaces. This powerful cooling system allows it to quickly lower indoor temperatures, ensuring a comfortable atmosphere even during the hottest summer days. Its heating function complements this by providing warmth during colder months, making it a versatile option for climate control.

Energy efficiency is a key characteristic of the Haier HSU-24HEK03/R2. Equipped with advanced inverter technology, this air conditioner optimizes power consumption by adjusting the compressor speed according to the cooling demand. This not only reduces energy bills but also contributes to a more sustainable environment. The unit often boasts a high EER (Energy Efficiency Ratio) rating, indicative of its ability to provide effective cooling with lower energy usage.

The multifunctional remote control enhances user convenience, allowing individuals to easily adjust settings from anywhere in the room. The easy-to-read display provides quick access to temperature settings, timer functions, and modes. Additionally, the unit features an intelligent auto-restart function that retains the last settings after a power interruption, providing seamless operation without constant readjustment.

Moreover, the HSU-24HEK03/R2 is designed to operate quietly, ensuring minimal disruption in daily activities. Its low noise level is especially beneficial for bedrooms, offices, and other quiet spaces where sound sensitivity is a concern.

Another essential feature is the comprehensive air filtration system. The unit is equipped with filters that effectively eliminate dust, allergens, and other airborne particles, ensuring that the air circulated in the room remains clean and healthy. Regular maintenance is also simplified with easy-to-clean, removable filters.

In summary, the Haier HSU-24HEK03/R2 stands out due to its powerful cooling and heating capabilities, energy efficiency, convenient remote operation, and effective air filtration. Its combination of technological advancements and user-friendly features makes it a compelling solution for climate control in various environments.