Deliming the water tank

Depending on your local water conditions, it may be necessary
to delime the water tank occasionally. Mineral buildup should
be removed from stainless steel surfaces to prevent corrosion
which may cause leaks.
Refer to the “Troubleshooting Guide” to determine if your
brewer needs to be delimed.
NOTE: For excessive lime build up, call an authorized service
center to have the tank removed and cleaned out.
1. Unplug brewer or disconnect power.
2. With the brew basket empty, place an empty decanter under
the brew basket.
3. Pour a quart of white vinegar or deliming agent into the pour
hole on top of the brew head. Let the vinegar remain in the
tank for three hours.
4. Plug in brewer or reconnect power.
5. Run 10 full brew cycles back-to-back through the system
using just water to remove the vinegar taste.

Storing the coffee brewer

If the coffee brewer will not be used for an extended period,
empty any water out of the reservoir and system, and clean
and dry it thoroughly.
Troubleshooting
Solution ...
Problem ...
Coffee maker spits water
or steams excessively
Inconsistent beverage
level in decanter
Weak beverage
Water tank, tank components, or
spray head are built up with lime.
Refer to “Deliming the water tank”
in the “How to Clean” section to
delime the brewer.
•A
12 -34cup variance is normal.
Wrong coffee grind. Use a fine or
drip grind for proper extraction.
Wrong type of filter. Use a high-
quality, name-brand filter.
Brew basket loaded incorrectly.
Level the coffee grounds by gently
shaking the basket.
Spray head partially blocked by
lime. Unscrew and remove to clean
away mineral deposits.
Spray head clogged with lime.
Refer to “Deliming the water tank”
in the “How to Clean” section to
delime the brewer.
Troubleshooting
Solution ...
Problem ...
Beverage overflows in
decanter
Decanter not empty when starting
brew cycle.
Filling vessel is larger than
decanter. Use same size.
Brew cycle will not start
Water is not hot
Brewer is making unusual
noises
ON/OFF switch not in ON position
or brewer not plugged in.
Water tank not filled with water.
Coffee brewer not plugged into
grounded outlet.
Check water tank for lime build up.
Tank or heating element needs to
be delimed. See “Deliming the
water tank” in the “How to Clean”
section.