4600rp, 4600g/4600r, 4800i User’s Guide 3 - 5

Note: Manual Trigger, Low Power cannot be used with keyboard wedge
applications.

Low Power Time-Out Timer

Scan the Low Power Time-Out barcode to change the time-out duration (in
seconds). Then scan the time-out duration (from 0-300 seconds) from the inside
back cover, and
Save
.
Default = 120 seconds.
If the unit remains idle during the low power time-out interval, the unit goes into
low power mode. Whenever the trigger is enabled, the low power time-out timer
is reset.
Note: This time-out does not begin until the imager time-out setting has expired.
In-Stand Sensor Mode (4600r only)
The 4600r (Software revision 31205480-118 or newer) contains a sensor that
senses when the imager is removed from the stand (HFSTAND5RSE only).
Refer to the Show Software Revision
on page 11-2
for information on
determining the software in your unit.
The imager then enters Manual Trigger
mode. If you wish to turn the sensor on, scan the Sensor ON barcode below.
Default = Off.
Scan Stand Mode
Note: Scan Stand Mode is only available for non-advanced illumination units
with software revision 31205480-090 or older. Refer to the Show
Software Revision on page 11-2 for information on determining the
software in your unit.
When a unit is in Scan Stand mode, it remains idle as long as it sees the Scan
Stand symbol. (See Scan Stand Symbol on page 3-6.) When a different code is
presented, the imager is triggered to read the new code.
Low Power Time-Out
Sensor On
* Sensor Off