Technical Information
Recommended water pressure 14.7 - 72.5 psi
Max. water pressure 147 psi
Recommended hot water temp. 120 - 140 F*
Max. hot water temp 165F*
Hole size in mounting surface 1 1/4” valves, 1 3/8” spout
Max. mounting surface depth 1 1/2”
Flow rate 2.2 gpm
Requires 1/2” supply lines (not included)
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. In
Massachusetts, the water heater may be set no higher than 112oF.
Install the hot and cold valves
Install the mounting nut, metal washer and the fiber
washer on the valve.
Insert the valve through the hole in the deck. The
hot valve is marked with a red dot.
Install the stop ring on the valve. Thread the mount-
ing plate on the valve until the stop ring stops it at
the proper height.
Rest the valve on the mounting surface. Turn the
valves so that the outlets point toward the center.
Tighten the mounting nut. Tighten the tensioning
screws.
Install the spout
Swing C and Limbo C only: Place the spout,
deco ring, and sealing ring on the mounting
surface.
All other models: Place the spout and sealing
ring on the mounting surface.
Installation