Measure the distance from the rough to the outside surface of the finished wall (X) (1).

Add 1 3/16” to X. Cut the spout connecting thread so that it is X + 1 3/16” long (2).

2.

1.

Wrap the spout connecting thread with Teflon tape. Install the spout connecting thread. Tighten it with an 8 mm Allen wrench.

Install the spout escutcheon and spout (1). Tighten the spout set screw with a 3 mm Allen wrench (2).

1.

2.

12