Set the High Temperature Limit Stop (optional):

Set the High Temperature Limit Stop (optional):

Turn off the water at the supply stops.

Close the drain or cover it with a cloth. Gently pry off the screw cover. Put it aside in a safe place. Use a 4mm hex wrench to loosen the handle screw (4 revolutions). Remove the handle and the decorative flange underneath.

Remove the nut.

Remove the handle screw from the stem of the cartridge.

Remove the high temperature limit stop.

Replace the high temperature limit stop so that the pin is in the desired notch. The temperatures marked on the diagram assume an incoming hot water temperature of 140o F and an incoming cold water temperature of 50o F and a water pressure of 45 psi. Your results will vary.

Replace the nut, nut cover, screw and handle.

User Instructions

Turn the water on by raising the handle. Lower the handle to turn the water off. Pivot the handle to the right for cooler water, to the left for warmer water.

When the faucet is turned on, the sprayhead is in the stream mode. Press the button on top of the sprayhead to activate the spray mode. When the water is turned off, the sprayhead will revert to the stream mode.

The spray channels on the handspray use the RubitTM cleaning system. If mineral deposits are noticed in the spray channels, turn the water on lightly and wipe the spray channels with your thumb or with a cloth.

If the flow of water diminishes over time, remove and clean the filter, located at the end of the handspray hose.