SKU 66351 For technical questions, please call 1-800-444-3353. Page 7

troubleshooting

Problem Possible causes likely solutions

Sewage Pump will not
start.
No power at outlet.1.
Circuit breaker tripped.2.
Cord not connected.3.
Water level too low. 4.
Check power at outlet.1.
Check circuit breaker for outlet.2.
Check that cord is plugged in.3.
Check water level.4.
Low ow from
discharge outlets.
Possible excess solid debris lodged 1.
in Impeller.
Check and clean debris from 1.
Impeller per instructions on Page 6.
Sewage Pump starts
and stops too often.
Possible back ow from discharge 1.
pipe and/or hoses.
Check-valve either not installed, or if 2.
installed, it is leaking.
Install a check-valve. 1.
Remove and examine check-valve 2.
for proper installation and operation.
Replace if necessary.
Sewage Pump
operates but delivers
little or no water.
Low line voltage. 1.
Debris caught in Impeller or 2.
discharge hoses or pipes.
Check-valve stuck closed or 3.
installed backwards.
If voltage is under recommended 1.
minimum, check wiring size from the
main switch on property. If not OK,
contact local power company.
Remove and check Impeller and 2.
discharge hoses or pipes. Clean if
needed.
Remove and examine check-valve 3.
and reinstall correctly or replace.

Follow all safety precautions whenever diagnosing or servicing the

appliance. disconnect power supply before service.

Please read tHe FollowIng careFully
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS qUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS
qUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR
DISTRIBUTOR ExPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE
UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER
ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL
PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION
OF REPLACEMENT PARTS THERETO.