Page 5
For Pump technical questions, please call 1-800-444-3353.Item 68375
For Engine technical questions, please call 1-800-520-0882.
The emission control system for this Pump’s Engine is
warranted for standards set by the U.S. Environmental
Protection Agency. For warranty information, refer to the
last pages of this manual.
Connecting Hoses
Note: Hose coupling components
and hoses not included.
Note: The Suction Hose (not included) MUST be
reinforced with braided material or have non-
collapsible construction. Do not use a hose
with an inside diameter smaller than 2″ (pump’s
intake and discharge port diameters).
CAUTION: Do not over-tighten Hose Clamps as the
clamp may damage the hose or other components.
1. Slide one of the Hose Coupling Rings over
one of the Hose Couplers (a), then place a
Gasket on the end of the Hose Coupler (b).
2.
Gasket
Hose Coupler
Hose Coupling Ring
a
b
Thread the Hose Coupling Ring onto the Intake Port
(a), and turn clockwise until fastened securely (b).
Intake Port
3. Slide one of the Hose Clamps over the end of the
suction hose (a). Slide the Hose onto the Hose
Coupler (b). Use a screwdriver (not included)
to tighten the Hose Clamp until secure.
CAUTION: Use only a non-collapsible intake hose.
4.
a
b
Hose Clamp
Suction Hose
Slide a Hose Clamp over the other end of the suction
hose (a). Slide the Intake Strainer into the end of the
suction hose (b). Use a screwdriver to tighten the Hose
Clamp until secure.
Intake Strainer
a
b
Set up