9.3 AMP Fuse (9): The 3 AMP Fuse is located on the rear panel of the Battery Charger. In the event the Power On (2) feature on any of the six separate cir cuits does not illuminate, turn Power Switch(es) (6) to the “OFF” positions and unplug the Battery Charger from its electrical outlet. Temporarily remove the Fuse Cap. Pull out and remove the 3 AMP Fuse to check for a melted wire strand within the Fuse. If necessary, insert a new 3 AMP Fuse into the Fuse Holder. Then replace the Fuse Cap. Plug the Power Cord of the Battery Charger into its electrical outlet, and turn the Power Switch(es) to the “ON” position to resume battery charging.

OPERATING INSTRUCTIONS

To Charge A Battery:

1.The Battery Charger features six separate circuits that allow the unit to charge up to six batteries at once.

2.To charge a battery, pull out the sliding Shelf on the Battery Charger, and place the battery on the Shelf. Connect the Charger Clamps (7) as discussed in Step #7, page 10.

3.Set the Current Selector (1) to the appropriate amperage (0.25, 0.50, or 0.90 AMPs). (See Figure D.)

4.Plug the Power Cord of the Battery Charger into the nearest 120 volt, grounded, electrical outlet.

5.Turn the Power Switch (6) (for the circuit you are using) to its “ON” position.

(See Figure D.)

6.When illuminated, the Battery Charged (4) feature will indicate the battery is fully charged. (See Figure D.)

7.Once the battery is fully charged, turn off the Power Switch (6). Unplug the Battery Charger from its electrical outlet. Then disconnect the Charger Clamps

(7) as discussed in Step #7, page 10. (See Figure D.)

8.When finished using the Battery Charger, make sure to store the Battery Charger in a clean, dry, safe location out of reach of children and other unauthorized people.

SKU 92775

For technical questions, please call 1-800-444-3353

PAGE 11

Page 11
Image 11
Harbor Freight Tools 92775 operating instructions Operating Instructions, To Charge a Battery