Maintenance
1.Keep this unit clean and dry. Unplug before cleaning. Clean only the outside of this unit with a soft, dry cloth; never clean this unit with water or cleaners.
2.Aside from the fuse, this device does not contain any user replaceable parts. If it needs service, take it to a qualified technician.
BEFORE INSPECTING THE FUSES, MAKE SURE THAT THE UNIT HAS
HAD AMPLE TIME TO COOL WITH NO LOAD.
3. | Charger Fuse Replacement |
|
|
| a. If the Inverter stops functioning in Charger mode, the charging fuse may | ||
| have blown. |
|
|
| b. The Charger’s fuse is underneath the AC Line Terminal. | ||
| c. Disconnect the Inverter from both the battery and the AC input. | ||
| d. Remove the fuse holder and in- |
|
|
| spect the fuse, see illustration. If |
|
|
| the fuse is intact, check the inter- |
|
|
| nal fuses as noted below. Other- |
|
|
| wise, replace the fuse ONLY with |
|
|
| another F10A250V |
|
|
| Amp, 250 Volt) fuse of the same |
|
|
| type. |
|
|
| e. Replace the fuse holder and recon- | Fuse |
|
| Holder |
| |
| nect the Inverter. Check for proper |
| |
|
|
| |
|
|
| |
| operation. |
|
|
4. | Internal Fuse Replacement |
|
|
a.If the Inverter stops functioning, one of the internal fuses may have blown.
b.Disconnect the Inverter from the battery, AC input, and all devices. Then, remove the Inverter from the vehicle.
c.Turn the Inverter upside down and remove the four black screws holding the cover on. Carefully set the back
cover aside. DO NOT TOUCH
INTERNAL PARTS.
d.Remove the fuses and inspect them; see illustration. If both fuses are intact and the unit still does not function, have the unit serviced by a qualified technician. Other- wise, replace damaged fuse(s) ONLY with 30 Amp fuse(s) of the same type.
e.Carefully reassemble, reinstall,
and reconnect the Inverter. Check | Internal |
|
|
for proper operation. | Fuses |
|
|
|
|
|
|
|
|
|
|
SKU 93096 For technical questions, please call | Page 7 |