Unpacking

When unpacking, check to make sure the parts listed on page 9 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number on the cover of this manual as soon as possible.

Operation

For best service, you should incorporate an oiler, regulator, and inline filter, as shown in the diagram below. Hoses, couplers, oilers, regulators, and filters are all available at Harbor Freight Tools.

Nailer

Note: To connect this tool, we recommend a quick coupler/adapter (not included). Coupler/ adapters are available at Harbor Freight Tools. If an automatic oiler is not used, put 3-5 drops of pneumatic tool oil in the Air Inlet (22) before each use.

Testing the Single Sequential SafetyTrip Mechanism

Warning: Even though the nailer should be empty during this procedure, ALWAYS point the nailer at a piece of scrap wood when testing.

1.Make sure the tool is disconnected from the power supply.

2.Completely empty the magazine of pins.

3.The Nailer should not fire if the nose is not depressed against the workpiece.

4.Check that the Trigger (42) and the Safety (48) move freely, without sticking - see Figure 1, next page.

5.Connect the air supply to the tool at the Air Inlet (22) set at the recommended 60-100 PSI, and not to go over the maximum 100 PSI.

6.Test the tool by depressing the Safety (48) against the workpiece without pulling the Trigger (42). The tool must not cycle (fire). If it cycles (fires), stop immediately and take the tool to an authorized service technician.

7.Hold the tool away or off of the workpiece. The Safety (48) of the tool should return to its original position. Squeeze the Trigger (42). The tool should not cycle (fire). If it cycles (fires), stop immediately and take the tool to an authorized service technician.

8.Depress the Safety (48) against the workpiece and squeeze the Trigger (42). The tool must cycle (fire). Release the trigger and squeeze it again. The tool must cycle (fire). With the Trigger held, carefully lift the nailer and press it against the workpiece again. The tool must not cycle (fire). If it fails to act in the manner described in bold, have it repaired by a qualified service technician.