IMPORTANT: The Spray Gun must be cleaned immediately after use.
Improper cleaning is a common reason for the Spray Gun not to work.
Fan Direction and Pattern Adjustment
Fan Direction
To change the direction of the fan from horizontal to vertical, loosen the Lock Ring and
turn the Air Cap (1A) 90 degrees. After the adjustment, tighten the Lock Ring by hand.
See FIGURE 3 below.
Pattern Adjustment
Warning!! Never exceed the Maximum Inlet PSI of MAX PSI.
1. Adjust the air pressure during operation with the Trigger (23A) fully depressed and the
Air Control Knob (25A) (see FIGURE 1 on page 6) fully open. If you need to reduce the
air pressure for specific areas, use the Air Control Knob (25A) or adjust the air com-
pressor.
2. To set the pattern size specific to the job, use the Pattern Control Knob (7A) (see
FIGURE 1 on page 6). By turning it counterclockwise (all the way open), the pattern
will flatten. Turn the Pattern Control Knob (7A) clockwise for a round pattern.
See FIGURE 4 below.
Flat/Open Round/Closed
FIGURE 3
Horizontal Fan
Vertical Fan
Air Cap
Lock Ring