Harman 4800 DriveRack, Section, Detailed Parameters, Auto On/Off switch, Attack fader, Hold fader

Models: 4820 4800

1 96
Download 96 pages 26.68 Kb
Page 66
Image 66
Auto On/Off switch

Section 6

 

 

 

 

DriveRack

 

 

 

®

 

 

Detailed Parameters

 

 

Auto On/Off switch

Auto mode dynamically sets the Attack, Hold, and Release parameters in real time, based on the incoming signal. This switch turns the Auto mode on and off.

Attack fader

The Attack parameter sets how quickly the compressor starts to compress the signal after it passes the threshold. The Attack can range between 0.1 mSec to 200 mSec. The Attack time is dynamically set while in Auto mode.

Hold fader

The Hold parameter is the time the 4800/4820 remains in compression after the signal has dropped back below the threshold. Hold is adjustable between 0 to 500 mSec and is dynamically set while in Auto mode.

Release fader

The Release parameter is the rate at which the Compressor comes out of compression once the signal is back below the threshold and the Hold time has elapsed. Release is measured in dB per second. For example, if Release is set to 5 dB/Sec, and the signal has 10dB of gain reduction, the release time is 2 Seconds. The Release range is from 360 dB/Sec to 5 dB/Sec. The Release rate is dynamically set while in Auto mode.

56

 

DriveRack® 4800/4820 User Manual

 

 

Page 66
Image 66
Harman 4800, 4820 DriveRack, Section, Detailed Parameters, Auto On/Off switch, Attack fader, Hold fader, Release fader