11
basement Installation
To install a DVC 500 in a basement you will need
additional DVC vent sections. These sections are
made with a 316-grade stainless steel liner and
a 20 gauge galvaneeled outer shell. Each joint is
sealed with a gasket and is bolted together with
4 bolts. In order to maintain the best seal, there
are no adjustable sections. There are straight, 45
degree, and Tee ttings. Refer to Page 14 for all
of the sections available.
Wall Termination
Tee with cover plate
Straight sections
Joint covers
Tee with cover plate
g. 10
g. 11
D
Never use venting other than harman dvC
venting inside the building. It is the only
vent certied for this appliance.
Refer to page 12 & 14 to calculate which sections
will be needed for your installation.
Corner Installation
A corner installation requires a 45 degree section
in addition to the standard wall termination.
In order to cut a hole in the wall that will allow the
stove to be placed an equal distance to each wall,
refer to Page 13.
Installation