Havis-Shields DS-PAN-411-2 Installation, thread locking adhesive to the threads of all fasteners

Models: DS-PAN-413 DS-PAN-412 PKG-DS-PAN-412-2 DS-PAN-411-2 PKG-DS-PAN-412 DS-PAN-411 DS-PAN-412-2

1 12
Download 12 pages 11.53 Kb
Page 6
Image 6
Installation

Installation

1)Remove the Mounting Bracket from the packaging. Install the Mounting Bracket to the Motion Device using (3) 1/4“-20 x 5/8” long screws (Hardware Kit Item 3). Torque screws to 80 in-lbs (9.0Nm) ± 10%.

NOTE: Numerous hole patterns present in Mounting Bracket will accomodate Havis Motion Devices as well as most competitors’

1/4”-20 Screws

Mounting Bracket

Typical Motion Device Example

(not included)

NOTE: We recommend applying a drop of medium strength (blue)

thread locking adhesive to the threads of all fasteners.

2)Lower the Docking Station to the Mounting Bracket as shown and secure with (4) 1/4”-20 x 5/8” long screws (Hardware Kit Item 3). Torque screws to 80 in-lbs (9.0 Nm) ± 10%.

1/4”-20 Screws

6

Page 6
Image 6
Havis-Shields DS-PAN-411-2, PKG-DS-PAN-412 Installation, NOTE We recommend applying a drop of medium strength blue