Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 B. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . 5

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 B. Tempered Glass Specifications . . . . . . . . . . . . . . . . . . . . . 7 C. BTU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 7 E. Non-Combustible Materials Specification. . . . . . . . . . . . . . 7 F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 7 G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 H. Requirements for the Commonwealth of Massachusetts. . 8

User Guide

2 Operating Instructions

A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 C. Fan Kit (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 D. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 E. Decorative Doors and Fronts . . . . . . . . . . . . . . . . . . . . . . 10 F. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 G. Remote Controls, Wall Controls and Wall Switches. . . . . 10 H. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . 10 I. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 11 J. Lighting Instructions (Standing Pilot) . . . . . . . . . . . . . . . . 12 K. After Fireplace is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 L. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 13

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . . 14 B. Maintenance Tasks-Qualified Service Technician . . . . . . 15

Installer Guide

4 Getting Started

A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 17

B. Design and Installation Considerations . . . . . . . . . . . . . . 18

C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . 18

D. Inspect Appliance and Components. . . . . . . . . . . . . . . . . 18

5 Framing and Clearances

A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . 19

B. Constructing the Appliance Chase . . . . . . . . . . . . . . . . . . 20

C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

D. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 21

6 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 22

7 Vent Information and Diagrams

A. Approved Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

B. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

C. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

D. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

E. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 33 B. Wall Penetration Framing. . . . . . . . . . . . . . . . . . . . . . . . . 34 C. Install the Ceiling Firestop . . . . . . . . . . . . . . . . . . . . . . . . 35 D. Install Attic Insulation Shield. . . . . . . . . . . . . . . . . . . . . . . 36

9 Appliance Preparation

A. Top Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

B. Rear Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

C. Securing and Leveling the Appliance . . . . . . . . . . . . . . . . 39

D. Completing Grate Set-up . . . . . . . . . . . . . . . . . . . . . . . . . 40

E. Checking Pilot Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

10 Installing Vent Pipe

A. Assemble Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . . 41 B. Assemble Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . . 42 C. Secure the Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . 42 D. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 43 E. Install Metal Roof Flashing. . . . . . . . . . . . . . . . . . . . . . . . 44 F. Assemble and Install Storm Collar . . . . . . . . . . . . . . . . . . 44 G. Install RF4-8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 H. Install Vertical Termination Cap . . . . . . . . . . . . . . . . . . . . 46 I. Heat Shield Requirements for Horizontal Termination . . . 46 J. Install Horizontal Termination Cap . . . . . . . . . . . . . . . . . . 47

11 Gas Information

A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 48

12 Electrical Information

A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 B. Intellifire Ignition System Wiring . . . . . . . . . . . . . . . . . . . . 49 C. Standing Pilot Ignition System Wiring . . . . . . . . . . . . . . . 49 D. Optional Accessories Requirements . . . . . . . . . . . . . . . . 49 E. Electrical Service and Repair . . . . . . . . . . . . . . . . . . . . . . 50 F. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 51 G. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 51

Heat & Glo • 8000TR-OAK, 8000TR-OAK-IPI, 8000TRLP-OAKIPI2057-900 Rev. P • 11/08

3

Page 3
Image 3
Hearth and Home Technologies 8000TRLP-OAKIPI, 8000TR-OAK-IPI owner manual Table of Contents, User Guide

8000TRLP-OAKIPI, 8000TR-OAK-IPI, 8000TR-OAK specifications

Hearth and Home Technologies is renowned for its innovative approach to home heating solutions, and their series of fireplaces is a testament to that commitment. Among their popular offerings are the 8000TR-OAK, 8000TR-OAK-IPI, and 8000TRLP-OAKIPI models. Each of these fireplaces is designed to deliver warmth, ambiance, and advanced technology wrapped in a refined aesthetic.

The 8000TR-OAK model features an impressive viewing area, which allows the flickering flames to be the centerpiece of any room. With a heating capacity that efficiently warms up spaces, it is ideal for both contemporary and traditional settings. One of its main highlights is the realistic log set that adds to the authenticity of the fire experience. The stove's design is not only visually appealing but also engineered for high efficiency, reducing carbon footprints while maximizing heat output.

Moving to the 8000TR-OAK-IPI, this model integrates the innovative IntelliFire Ignition system, ensuring that operation is reliable and energy-efficient. The IPI system allows the fireplace to be controlled with ease, offering both manual and remote-operation options. This model maintains the authentic charm of the traditional fireplace while incorporating modern technology. The 8000TR-OAK-IPI also boasts multiple flame settings, giving users the flexibility to adjust their experience based on mood or season, along with an outstanding ability to maintain heat with minimal energy consumption.

The 8000TRLP-OAKIPI takes versatility a step further by operating on liquid propane, making it ideal for homes that are not connected to natural gas lines. Along with the IntelliFire Ignition technology, this model ensures exceptional efficiency, making it a premium choice for those who prioritize sustainable energy solutions. The design retains the luxurious oak finish found in its counterparts, ensuring it complements any interior decor seamlessly.

All three models share a range of characteristics that set them apart: a robust construction that promises longevity, an array of customizable options, and built-in safety features that instill confidence in operation. They also offer a variety of venting options, giving homeowners flexibility in installation. With Hearth and Home Technologies’ commitment to quality and innovation, the 8000 series fireplaces provide not just heat, but a captivating focal point for home gatherings.