LISTINGS AND SPECIFICATIONS
HEAT INPUT*: | 28,000 to 37,500 BTU per hour |
PARTICULATE EMISSIONS PER HOUR: | 0.9 grams per hour |
DIMENSIONS: |
*BTU INPUT WILL VARY, DEPENDING ON THE BRAND OF FUEL YOU USE IN YOUR STOVE. CONSULT YOUR
INSTALLATION
CLEARANCES TO COMBUSTIBLES
Minimum Clearances To Combustible Material (USA in inches, Canada in mm).
RESIDENTIAL/MOBILE HOME | RESIDENTIAL/MOBILE HOME | RESIDENTIAL/MOBILE HOME | RESIDENTIAL/MOBILE | ||||
HOME |
|
|
|
|
|
| |
A = 8” (150mm) | A = 8” (150mm) |
| F = 2” (50mm) | C = 3” (75mm) D = 8” (200mm) | |||
B = 2” (50mm) | C = 3” (75mm) |
| Horizontal and Vertical | (from side of the stove face) | |||
Horizontal Installation | Vertical Installation | Comer Installation | E = 2” (50mm) | ||||
|
| with 6” (152mm) Top Vent Kit |
|
|
|
| |
|
|
|
|
| |||
|
| CLEARANCES TO COMBUSTIBLES (USA IN INCHES, CANADA IN MM) |
|
| |||
|
|
|
| Top Vent | Top Vent |
|
|
|
|
| Rear | Kit With | Kit With |
|
|
|
|
| Vent | 3” Pipe | 6” Pipe |
|
|
| Back: |
| 2” (50mm) | 8” (200mm) | 9” (225mm) |
| |
| Side: |
| 2” (50mm) | 2” (50mm) | 2” (50mm) |
| |
| Corner: |
| 2” (50mm) | 2” (50mm) | 2” (50mm) |
| |
| From side of stove face: | 8” (200mm) | 8” (200mm) | 8” (200mm) |
| ||
|
|
|
|
|
|
|
|
CHIMNEY AND EXHAUST CONNECTION
1 . CHIMNEY & CONNECTOR: Use 3” (76mm) or 4” (102mm) diameter type “L” or ”PL” venting system.
2.MOBILE HOME: Approved for all listed pellet vent. If using the 3" (76mm) or 6" (152mm) vertical top vent kit, you must use either listed double wall flue connector to Class A pipe, or all Class A pipe. Mobile home venting system must be equipped with a spark arrestor and rain cap.
3.RESIDENTIAL: The 3" (76mm) and 6" (1 52mm) vertical top vent kits are tested to use 24 gauge single wall flue connector or listed double wall flue connector to Class A listed metal chimneys or masonry chimneys meeting ICBO standards for solid fuel appliances.
4.The stove is approved for all 3" (76 mm) or 4" (102 mm) diameter listed pellet vent. It can be either vertically or horizontally vented.
NOTE: All pipe must be sealed using welded seam pipe whenever possible. Seal pipe joints with high temperature silicone (500°F [260°C] minimum rated only).