Honeywell K14114 3/06 Rev.B setup guide Specifications, Contacting Technical Support, Electrical

Models: K14114 3/06 Rev.B

1 72
Download 72 pages 35.87 Kb
Page 70
Image 70
Specifications

LYNXR-I Installation and Setup Guide

Specifications

LYNXR-I

Security Controls

1.Physical: 10-3/8” W x 7-1/8” H x 1-3/4” D

2.Electrical:

VOLTAGE INPUT: 9VAC from plug-in 25VA transformer.

RECHARGEABLE BACKUP BATTERY: Nickel-metal hydride battery pack rated at 7.7Vdc.

ALARM SOUNDER: Piezo = 6-14VDC, 30mA max/ Bell = 6-14VDC, 120mA max (e.g., ADEMCO’s WAVE2EX).

3.Communication:

FORMATS SUPPORTED:

ADEMCO Express, 10 characters/sec, DTMF (TouchTone) Data Tones, 1400/2300Hz ACK, 1400Hz KISSOFF.

ADEMCO Contact ID® Reporting, 10 characters/sec., DTMF (TouchTone) Data Tones, 1400/2300Hz ACK, 1400Hz KISSOFF.

ADEMCO Low Speed, 10 pulses/sec, 1900Hz Data Tone, 1400Hz ACK/KISSOFF.

Radionics/SESCOA, 20 pulses/sec, 1800Hz Data Tone, 2300Hz ACK/KISSOFF. Can report 0–9, B–F.

Line Seize: Double Pole

Ringer Equivalence: 0.6B

FCC Registration No.: 5GBUSA-25623-AL-E

Contacting Technical Support

PLEASE, before you call Technical Support, be sure you:

READ THE INSTRUCTIONS!

Check all wiring connections.

Determine that the power supply and/or backup battery are supplying proper voltages.

Verify your programming information where applicable.

Note the proper model number of this product, and the version level (if known) along with any documentation that came with the product.

Note your ADEMCO customer number and/or company name.

Having this information handy will make it easier for us to serve you quickly and effectively.

You may contact Technical Support via Toll Free Fax. Please include your return fax number. You will receive a reply within 24 hours.

Technical Support:

1-800-645-7492 (8 a.m.-8 p.m. E.S.T.)

FAX FAXBACK Automated Fax Retrieval System:

1-800-573-0153 or 1-516-921-6704 / ext. 1667

World Wide Web Address:

http://www.honeywell.com/security

 

 

- 70 -

Page 70
Image 70