LYNXR-I Installation and Setup Guide

Data Field Descriptions

DOWNLOAD INFORMATION (94, 95)

94

Download Call Back Phone Number

This is the phone number the control will use to call back the downloading

Enter up to 20 digits as follows: 0–9, # +11 for “*”, #

computer.

 

Do not fill unused spaces. End field by pressing . To clear entries from

 

+ 12 for “#”, # + 13 for a pause.

 

field, press 94.

 

 

 

 

 

95

Ring Detection Count For Downloading/

Enter “15” to select defeat answering machine mode. If an

Remote Phone Control

answering machine is on the premises, you need to dial the

 

 

0 = disable station initiated download and remote

premises and hang up on the first ring. Wait at least five (5)

 

seconds (but no more than 22 seconds) and dial the premises

 

phone

 

phone number again. The control will pick up and announce

 

1-14 = number of rings before control picks up phone

 

“SYSTEM ENTER CODE” every three seconds.

 

line

 

15 = defeat answering machine

Note: To enter a number higher than 9 you must first press the [#] key.

 

 

 

OTHER PROGRAMMING COMMANDS

56 ENHANCED ZONE PROGRAMMING MODE

Interactive menu mode used for programming zone attributes and report codes. Refer to the 56 Enhanced Zone Programming Mode section for procedure.

80 DEVICE PROGRAMMING MENU MODE

Interactive menu mode for programming Powerline Carrier Devices. Refer to the 80 Device Programming Menu Mode section for detailed procedure.

81 ZONE LISTS MENU MODE

Interactive menu mode for programming zone lists for Powerline Carrier Devices. Refer to the 81 Zone List Menu Mode section for detailed procedure.

83 ENHANCED SEQUENTIAL MODE

Interactive menu mode used to enter RF transmitter serial numbers. Refer to the 83 Enhanced Sequential Mode section for detailed procedure.

84 ASSIGN ZONE VOICE DESCRIPTORS

Interactive menu mode used to assign descriptors to each zone. These descriptors will be announced whenever the system announces an event involving a zone.

85 RECORD CUSTOM VOICE DESCRIPTORS

Interactive menu mode used to record custom descriptors for use with each zone.

96 INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. NO. FOR

DOWNLOADING

Pressing 96 initializes the system for downloading.

97 SET ALL PROGRAM FIELDS TO 1 OF 4 SETS OF DEFAULT VALUES

See Default Tables at the end of this manual.

98 EXITS PROGRAMMING MODE

Prevents re-entry by: Installer Code + 8 + 0 + 0; allows re-entry only by Power-up, then [] and [#].

99 EXITS PROGRAMMING MODE

Allows re-entry to program mode by: Installer Code + 8 + 0 + 0; or by Power-up, then [] and [#].

- 28 -