Honeywell K14114 3/06 Rev.B Enhanced Zone Programming Mode, LYNXR-IInstallation and Setup Guide

Models: K14114 3/06 Rev.B

1 72
Download 72 pages 35.87 Kb
Page 31
Image 31

 

 

 

 

 

 

 

LYNXR-I Installation and Setup Guide

 

 

 

 

 

 

 

56 Enhanced Zone Programming Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop number or Loop and Serial

This prompt can be used to enroll loop number and serial number via

 

 

 

E

 

 

 

 

l

 

number (if using RF Learning)

RF transmission or the loop number can be enrolled manually. If

 

 

 

 

using the RF Learning Mode, there is no need to manually enter a

 

 

 

 

1-4 = loop number for the zone of the transmitter

 

 

 

 

 

loop number. Proceed directly to RF Learning

 

 

 

 

 

 

being entered.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 + [] = continue to DELETE ZONE

Notes: (1) BR type devices cannot be enrolled by using UR or RF

 

 

 

 

 

 

PARAMETERS CONFIRMATION prompt

type. Likewise, UR or RF type devices cannot be enrolled

 

 

 

 

 

 

(F)

by using a BR type device. There is a 52-second time-out

 

 

 

 

 

 

[] = continue to the ENROLL MODE prompt

for RF enrolling. At the end of the time-out, the system

 

 

 

 

 

 

(1A) if not entered, or VOICE DESCRIPTOR

returns to the INPUT TYPE prompt (d). If enrolled, loop

 

 

 

 

 

 

number and “L” are displayed.

 

 

 

 

 

 

prompt if already entered

 

 

 

 

 

 

(2) Once encrypted (high-security) devices have been enrolled

 

 

 

 

 

 

[#] = return to previous prompt

 

 

 

 

 

 

they must be activated. Refer to the device’s Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructions to activate the High-Security Mode. RF

 

 

 

 

 

 

 

Learning - Two (2) transmissions (2 key depressions) at

 

 

 

 

 

 

 

least 5 seconds apart will be required for BR type devices

 

 

 

 

 

 

 

(device type 5). Two beeps will sound after the second

 

 

 

 

 

 

 

transmission, confirming that the loop number and serial

 

 

 

 

 

 

 

number have been learned.

 

 

 

 

 

 

 

For all other device types, four (4) transmissions are required (fault,

 

 

 

 

 

 

 

restore and fault, restore). A single beep will sound after the second

 

 

 

 

 

 

 

transmission confirming that the loop and serial number have been

 

 

 

 

 

 

 

captured. Following the fourth transmission the system will confirm

 

 

 

 

 

 

 

that the loop number and serial number have been learned and

 

 

 

 

 

 

 

announce the Voice Descriptor for the zone, if it is programmed,

 

 

 

 

 

 

 

followed by two beeps.

 

 

 

 

 

 

 

Press [] to continue.

 

 

 

 

 

 

 

Manual Entry - Enter the desired loop number and press [] to

 

 

 

 

 

 

 

continue (see the transmitter’s Installation Instructions for specific

 

 

 

 

 

 

 

loop designations).

 

 

 

 

 

 

 

Note: The loop number can be changed even if the zone has already

 

 

 

 

 

 

 

been entered. Care should be taken when using this feature as

 

 

 

 

 

 

 

it has the capability to make zones inoperable by creating a

 

 

 

 

 

 

 

mismatch of a working serial number/loop number

 

 

 

 

 

 

 

combination. This should be re-confirmed if the loop number is

 

 

 

 

 

 

 

changed.

 

 

 

 

 

 

 

“L” indicates that the zone’s serial number has already been enrolled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Delete zone parameters confirmation

This function deletes either the serial number or all zone information

 

 

 

F

 

 

 

 

 

 

0 = discard the delete request

that is programmed for the zone.

 

 

 

 

 

If “00” was entered in the zone type, the confirmation of the delete

 

 

 

 

 

1 = confirm requested delete

 

 

 

 

 

request will delete all information associated with the zone currently

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: If 00 was entered as a zone type in prompt (b), 00

being programmed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

will be retained and system will advance to

If “0” was entered in the loop number, the confirmation of the delete

 

 

 

 

 

 

prompt (1C).

 

 

 

 

 

 

request will delete the serial number of to the zone currently being

 

 

 

 

 

 

 

 

 

 

 

 

 

 

programmed.

 

 

 

 

 

 

 

 

 

- 31 -

Page 31
Image 31
Honeywell K14114 3/06 Rev.B setup guide Enhanced Zone Programming Mode, LYNXR-IInstallation and Setup Guide