Honeywell K14114 3/06 Rev.B Data Field Descriptions, LYNXR-IInstallation and Setup Guide

Models: K14114 3/06 Rev.B

1 72
Download 72 pages 35.87 Kb
Page 26
Image 26
Enable/Disable

LYNXR-I Installation and Setup Guide

Data Field Descriptions

To ensure that the LYNXR-I properly transmits its reports to the Central Station via the proper channel you must program a Primary Phone Number in Field *41 and/or activate/deactivate the LRR/IP Communications Module in Field *55.

The 15-Second Dialer Delay (Burglary), programmed in Field in *50 is independent of the delay selected in Field *77 and applies to both telephone and communications device.

DYNAMIC SIGNALING DELAY/DYNAMIC SIGNALING PRIORITY FIELD 77

Two report channels are used by the LYNXR-I to support the LRR/IP communications device and dynamic signaling. For the primary channel the device can communicate via LRR, Cellular GSM, or Internet (IP). Secondary phone is not affected by dynamic signaling scheme. Two programming options are used to define dynamic signaling behavior. Field *55 is used to enable/disable the LRR/IP communications device and allows it to supervise the communications module. The two-digit option programmed in Field *77 defines how dynamic signaling will function. The Dynamic signaling options are shown below:

 

Enable/Disable

Dynamic Signaling Delay/Dynamic Signaling

Reporting Option
Device (Field *55)
(Field *77)
Primary Phone only

0 = Disable

1st Entry

Report is sent to Primary phone with No Dynamic Signaling

 

Enter Any Digit

Delay

 

2nd Entry

 

 

Enter “0”

LRR/IP Communications Device only

1 = Enable

1st Entry

Report sent to communications device with No Delay

 

* = enter any non zero digit as a first entry

 

 

2nd Entry

 

 

2 = LRR/IP reporting only

Redundant reports to both channels

1 = Enable

1st Entry

Report independently goes to the Primary phone and LRR/IP

 

0 = Redundant reporting on dialer and comm. device

communications device with No Delay

 

2nd Entry

 

 

* = enter any number as a second entry

Primary Phone is the preferred channel

1 = Enable

1st Entry

First report is sent to the primary phone. If primary phone fails to

 

* = enter a delay for the first entry

deliver report within the delay window defined in *77 all following

 

2nd Entry

reports go to both primary phone and communications device

 

0 = Primary Dialer is the preferred channel

with no delay. When report goes through the primary phone,

 

 

LYNXR-I stops reporting to communications device.

 

 

Note: The delay must be set to at least 30 seconds if Remote

 

 

Phone Control and/or AAV is enabled.

 

 

 

 

 

LRR/IP Communications Device is the preferred channel

1 = Enable

1st Entry

First report is sent to the communications device. If device fails to

 

* = Enter any delay for the first entry

deliver report within to deliver report within the time window

 

2nd Entry

defined in *77 all following reports go to both LRR/IP device and

 

1 = LRR/IP is the preferred channel

primary phone with no delay. When report goes through the

 

 

LRR/IP device LYNXR-I stops reporting to primary phone.

 

 

 

 

 

Note: If the LRR/IP communications device is selected as the preferred channel option and the LYNXR-I detects a communication failure or supervision failure, reports will be sent to the Primary Phone without any delay.

77

Dynamic Signaling Delay/ Dynamic

Intended for use with LRR/IP communication device reporting.

Signaling Priority

 

This field’s 1st Entry allows you select the time the panel will

 

 

 

1st Entry (delay before switching Central Station

wait for acknowledgment from the first reporting destination

 

(preferred channel) before it attempts to send a message to the

 

reporting path)

7 = 105 seconds

second destination. This delay is per message. The 2nd entry

 

0

= Redundant reporting

allows you to select the preferred reporting channel.

 

 

on dialer and LRR/IP

8 = 120 seconds

 

 

Notes: (1)

You must also enable/disable LRR/IP Device in field *55.

 

 

communications

9 = 135 seconds

(2)

If Remote Phone Access is enabled, and Primary Phone is

 

 

device

#10 = 150 seconds

 

used as a Preferred Channel, Dynamic Signaling Delay

 

1

= 15 seconds

#11 = 165 seconds

 

should be at least 30 sec in order to prevent duplicate

 

2

= 30 seconds

#12 = 180 seconds

 

reports.

 

3

= 45 seconds

#13 = 195 seconds

(3)

For UL installations Dynamic Signaling Delay cannot exceed

 

4

= 60 seconds

#14 = 210 seconds

 

15 sec. If Primary Phone is used as a Preferred Channel,

 

5

= 75 seconds

#15 = 225 seconds

1st Entry

duplicate reports may sent.

 

6

= 90 seconds

 

 

 

 

 

 

Enables Dynamic Signaling Delay. The entry of digits 1-9 or #10-

 

2nd Entry

 

#15 will control the time-out period the panel will wait for an

 

 

acknowledgment from the first reporting destination. Delays can

 

0 = Primary Dialer Preferred Channel

 

be selected from 0 to 225 seconds, in 15-second increments. If 0

 

1 = LRR/IP Preferred Channel

 

 

 

is entered, the control panel will send redundant reports to both

 

2 = LRR/IP reporting only

 

 

 

Primary Dialer and the LRR/IP communications device.

 

 

 

 

 

 

 

 

2nd Entry

 

 

 

 

The second entry determines the Dynamic Signaling Priority.

 

 

 

 

The alternate Central Station communication path will be

 

 

 

 

initiated After the time-out period.

- 26 -

Page 26
Image 26
Honeywell K14114 3/06 Rev.B Data Field Descriptions, LYNXR-IInstallation and Setup Guide, Dynamic Signaling Delay/ Dynamic