Honeywell K14114 3/06 Rev.B Loading Factory Defaults, Pass-ThruProgramming, Interactive Mode

Models: K14114 3/06 Rev.B

1 72
Download 72 pages 35.87 Kb
Page 17
Image 17
Interactive Mode

LYNXR-I Installation and Setup Guide

Interactive Menu Mode Programming (56, 80, 81, 83, 84, 85)

Press [] + interactive mode No. (i.e., 56). The keypad will display the first of a series of prompts. A detailed procedure (with displays of prompts) is provided in later sections of this manual.

 

Interactive Mode

Used to Program

56 Enhanced Zone Programming Mode

Zone characteristics, report codes, and serial numbers

80 Device Programming Menu Mode

Powerline Carrier Devices

81

Zone List Menu Mode

Zone Lists for powerline carrier activation

83

Enhanced Sequential Mode

5800 Series transmitter serial numbers

84

Assign Zone Voice Descriptors

Voice descriptors for each zone

85

Record Custom Voice Descriptors

Up to 5 custom voice descriptors for zones

Loading Factory Defaults

To load the factory defaults, enter the Programming mode, press 97, then press number 1, 2, 3, or 4 to select from default tables 1-4 at the back of this manual, or press “0” if you are not selecting a default table.

If a default table is loaded, any data that has already been programmed into the system will be changed according to the default table selected!

96 resets all subscriber account numbers and CSID in preparation for an initial download.

Exiting Program Mode

98 inhibits re-entry into the Expert or Voice Prompt Programming modes using the Installer Code.

99 allows re-entry into the Expert Program mode using Installer Code (4112) + 800 or into the Voice

Prompt Programming mode using Installer Code (4112) + 888.

Note: After exiting program mode (or upon power-up), the system takes up to a minute to reset. To bypass the reset delay, press [#] + [0].

Pass-Thru Programming

This mode allows the Installer to use the LYNXR-I keypad and display to program the communications device that is connected to the LYNXR-I. Refer to the communications device’s installation instruction to determine whether this feature is supported.

Entering Pass-Thru Programming mode

1.After power-up, enter the Installer Code (4112) + 899.

2.Once you have entered Pass-Thru Programming mode “PtP” will be displayed on the keypad.

3.Refer to the Installation Instructions for the LRR/IP Communications Device being installed for additional programming information.

LYNXR-I will abort this mode:

When it receives an abort command from the new communications device.

If it fails to communicate with an communications device after 20 attempts.

30 minutes after the last key has been pressed.