Enroll mode

LYNXR-I Installation and Setup Guide

 

56 Enhanced Zone Programming Mode

 

 

 

 

 

 

 

 

 

 

 

Enroll mode

If “L” is displayed, the serial number for this transmitter has already

 

IA

LC

 

0 = advance to the VOICE DESCRIPTOR

been entered. It may, however, still be viewed, confirmed (only if in

 

 

listen mode), or deleted.

 

 

prompt (1C).

 

 

 

 

 

 

 

 

 

Note: This will save all zone parameters.

View serial number

 

 

 

 

 

1 = enter now and proceed to SERIAL

 

 

 

 

 

Enter “3”. Each digit will be redisplayed, and the keypad will beep once

 

 

 

 

 

NUMBER prompt (1b).

for digits 1-6, and three times for the last digit.

 

 

 

 

 

Note: Not applicable if the serial number is already

 

 

 

 

 

 

 

present.

Confirm serial number

 

 

 

 

 

2 = copy the last serial number entered into

The serial number/loop number combination can be confirmed after one

 

 

 

 

 

transmission from a BR type device or two transmissions (fault and

 

 

 

 

 

local ram.

 

 

 

 

 

restore) from a UR or RF type device. If a transmission is received that

 

 

 

 

 

Note: If this is the 1st zone, none will be in the buffer

 

 

 

 

 

matches the serial number and loop number entered, the system will

 

 

 

 

 

and the panel will emit a long tone. Not valid if

confirm the reception by announcing the Voice Descriptor for the zone,

 

 

 

 

 

serial number is already present.

if it is programmed, followed by three beeps, and a “C” will appear on

 

 

 

 

 

3 = view existing serial number.

the display indicating the received serial number and loop number

 

 

 

 

 

Note: Only if “L” is displayed. If “L” is not displayed,

have been confirmed. No further transmissions will be received.

 

 

 

 

 

panel will emit a long beep.

Delete serial number

 

 

 

 

 

9 = advance to F; delete existing serial

 

 

 

 

 

The serial number can be deleted by entering “9”.

 

 

 

 

 

number.

 

 

 

 

 

 

 

 

 

 

 

 

Note: Only if “L” is displayed. If “L” is not displayed,

If “L” is not displayed, the serial number for this transmitter has not

 

 

 

 

 

panel will emit a long beep.

 

 

 

 

 

been previously entered. You may enter the serial number manually,

 

 

 

 

 

[] = advance to the VOICE DESCRIPTOR

 

 

 

 

 

copy the previous serial number, return to Prompt (E) or enter the

 

 

 

 

 

prompt (1C). This will save all zone

serial number later using the 83 Enhanced Sequential Mode.

 

 

 

 

 

parameters.

Manual entry

 

 

 

 

 

[#] = return to the LOOP NUMBER prompt (E).

 

 

 

 

 

Enter "1" to advance to Serial number prompt (1b).

 

 

 

 

 

Note: In order for all entered parameters to be

 

 

 

 

 

Copy the previous serial number

 

 

 

 

 

accepted, you must advance to the VOICE

Enter “2” to copy the previous serial number entered.

 

 

 

 

 

DESCRIPTOR prompt (1C).

Return to Prompt (E)

 

 

 

 

 

 

Enter “#” to return to Loop Number prompt (E).

 

 

 

 

 

 

Enter transmitter later

 

 

 

 

 

 

Enter “0” or “” if you wish to enter the transmitter later, using the

 

 

 

 

 

 

83 Enhanced Sequential Mode described later in this manual.

 

 

 

 

 

 

Notes: (1) The panel will listen only when it is in the idle loop waiting

 

 

 

 

 

 

for key entry and a serial number has been entered. If a key

 

 

 

 

 

 

is entered, the function must be completed and the panel

 

 

 

 

 

 

will listen again.

 

 

 

 

 

 

(2) A long beep indicates illegal entry or duplicate serial number/loop

 

 

 

 

 

 

entry

 

 

 

 

 

Serial number

In this mode, the transmitter serial numbers can only be entered

 

Ib

 

 

 

Enter the transmitter’s 7-digit serial number.

manually.

 

 

 

 

 

 

 

 

 

 

 

[#] = return to prompt 1A and reject any serial

Enter the

7-digit serial number printed on the transmitter. If an

 

 

 

 

 

numbers entries that have been made.

 

 

 

 

 

incorrect digit is entered, press the [#] key to backup to prompt (1A)

 

 

 

 

 

[] = return to prompt 1A, (if a valid serial

 

 

 

 

 

and start over. When all 7 digits are entered, press the [] key.

 

 

 

 

 

number has been entered, the "L" is

 

 

 

 

 

 

 

displayed and the serial number will be

If 52 seconds passes and no entry has been made, the system returns

 

 

 

 

 

copied into EEROM from the last serial

to prompt (1A).

 

 

 

 

 

entered into the buffer.)

Notes: (1) If the serial and loop number combination is already

 

 

 

 

 

Note: This prompt can be used only to manually

 

 

 

 

 

 

present the keypad will emit a single long beep and the

 

 

 

 

 

enroll a serial number. RF enrollment will be

 

system will return to the (1A) prompt and “L” will be

 

 

 

 

 

rejected and the current zone descriptor will be

 

displayed.

 

 

 

 

 

announced, followed by a single long beep

(2)

If less than 7 digits have been entered, the keypad will

 

 

 

 

 

and the system will return to prompt (1A).

 

emit a single long beep and return to the (1A) prompt

 

 

 

 

 

 

 

without displaying the “L”.

 

 

 

 

 

 

(3)

If more than 7 digits have been entered, the first 6 digits

 

 

 

 

 

 

 

will be saved along with the last digit that was entered

 

 

 

 

 

 

 

(entering 123456789 yields the serial number 1234569).

 

 

 

 

 

 

 

 

 

 

 

 

Voice descriptor

Each zone can have a voice descriptor of up to 3 words that will be

 

IC

 

 

 

0 = skip to next zone (A)

announced whenever the system announces status for that zone.

 

 

 

 

 

 

 

 

 

 

1 = enter descriptor mode; existing descriptor

 

 

 

 

 

 

 

for this zone will be announced

 

 

 

 

 

 

 

 

 

 

- 32 -

Page 32
Image 32
Honeywell K14114 3/06 Rev.B setup guide Enhanced Zone Programming Mode, LYNXR-IInstallation and Setup Guide, Enroll mode