AC Power and Rechargeable Backup Battery

LYNXR-I Installation and Setup Guide

AC Power and Rechargeable Backup Battery

The LYNXR-I is equipped with an integral, replaceable, rechargeable battery pack rated at 7.7Vdc. Select the appropriate battery pack, based on the installation’s requirement, and install the battery pack.

Model/Part Number

Battery StandbyTime

Low Battery Notification

LYNXRCHKIT-SC

4-hours (minimum)

Approximately 1-hour before battery depletion

 

 

 

LYNXRCHKIT-HC

24-hours (minimum)

At least 1-hour before battery depletion

 

 

 

LYNXRCHKIT-SHA

24-hours (minimum)

At least 1-hour before battery depletion

 

 

 

Replacing the Rechargeable Battery

1.When battery replacement is required, unplug the transformer from the wall outlet, and open the control panel cover.

2.Remove the battery retainer and disconnect the battery pack connector from the receptacle on the terminal block PC board.

3.Remove the battery pack from the back plate.

4.If required, replace the tape that secures the battery pack.

5.Install a replacement battery pack (P/N LYNXRCHKIT-SC, LYNXRCHKIT-HC or LYNXRCHKIT-SHA) into the back plate.

6.Install the battery retainer.

7.Connect the battery connector to the receptacle on the terminal block PC board.

8.After the wiring connection has been made, snap the front assembly to the back plate.

9.Plug the transformer into a 24-hour, 110VAC unswitched outlet.

10.Rechargeable batteries may take up to 48- hours to fully charge. The “LOW BAT” message should clear within four hours or by entering Test Mode.

LYNXRCHKIT-HC OR LYNXRCHKIT-SC

RETAINER Replacing the Rechargeable Battery

BATTERY

PACK

TAPE

Manual backgroundManual background BATTERY CONNECTOR

BATTERY

RECEPTACLE Manual backgroundManual background

LYNXRCHKIT-SHA

RETAINERManual background

BATTERY

PACK

BATTERY

TAPE

CONNECTOR

 

BATTERY

RECEPTACLE Manual backgroundManual background

07000-006-V1

Ensure the control panel assembly is snapped closed prior to applying AC power.

- 12 -