AC Power and Backup Battery

LYNXR-I Installation and Setup Guide

AC Power and Backup Battery

The system is powered by a 9VAC, 25VA Plug-in Transformer, ADEMCO K10145X10 (K10145CN in Canada). Refer to the wiring table below for wire gauge and length.

Use only the provided ADEMCO K10145X10 or K10145CN Transformer.

Distance from Transformer

Wire Gauge

to Control

 

 

 

Up to 75 feet

#20

 

 

75 to 150 feet

#18

 

 

150 to 300 feet

#16

 

 

Wiring to the AC Transformer must not exceed 300 feet using 16-gauge wire. The voltage reading between terminals 15 and 16 of the control must not fall below 9.00VAC.

Do not plug the transformer into the AC outlet until after all wiring connections have been made.

Backup battery

In the event of an AC power loss, the system is supported by a long life backup battery that is supervised for connection and for low voltage conditions. If the battery is missing, or a low battery condition is detected, a “low battery” message is displayed and a report is sent to the central station. In addition, the system will beep once every 45 seconds to audibly indicate a low battery condition (press any key to stop the beeping).

AC Power and Rechargeable Backup Battery

Connecting AC Power and backup battery

1.Connect wires from the K10145X10 (K10145CN) in Canada) AC Transformer to terminals 15 and 16 as shown in the wiring diagram.

2.Remove battery retainer.

3.Peel the backing from tape on the back plate.

4.Insert battery pack into back plate.

5.Install battery retainer.

6.Connect battery connector to receptacle on terminal block PC board.

7.After all wiring connections have been made, snap the front assembly to the back plate and plug the transformer into a 24-hour, 110VAC unswitched outlet.

Note: Rechargeable batteries may take up to 48-hours to fully charge. The “LOW BAT” message should clear within four hours or by entering Test Mode.

RETAINER

BATTERY

PACK Backup battery

TAPE

NOTE

LYNXRCHKIT-HC

BATTERY PACK SHOWN

BATTERY

WIRING

 

RECEPTACLE

TERMINALS

07000-007-V0

Ensure the cover is snapped closed prior to applying AC power.