LYNXR-I Installation and Setup Guide

Wiring Connections

1.Make Earth Ground Connection - The designated earth ground terminal (1) must be terminated in a good earth ground for the lightning transient protective devices in this product to be effective. The following are examples of good earth grounds available at most installations:

Metal Cold Water Pipe - Secure a non-corrosive metal strap (copper is recommended) to the pipe that is electrically connected and secured to which the ground lead is electrically connected and secured.

AC Power Outlet Ground - Available from 3-prong, 120VAC power outlets only. To test the integrity of the ground terminal, use a three-wire circuit tester with neon lamp indicators, such as the UL Listed Ideal Model 61–035, or equivalent, available at most electrical supply stores.

a. Connect terminal 1 to a good earth ground.

2.Make Phone Line Connections - For local or full line seizure proceed to the appropriate steps below.

Local Seizure

a.Connect the incoming phone line to either the 8-position jack or terminals 2 (TIP) and 3 (RING) on the Lynx.

b.Connect the handset phone lines to either the RJ11 jack or terminals 4 (TIP) and 5 (RING).

Full Line Seizure: The control must be placed in series with the incoming phone line. Plugging the Direct Connect Cord directly into the RJ31X jack, allows the control to seize the phone line when an alarm occurs and normal phone line usage by the premises phones if the plug needs to be removed.

c.Cut the incoming RING and TIP phone lines (typically red and green, respectively) and connect them to RJ31X terminals 4 (red) and 5 (green).

d.Connect the premises end of the cut RING and TIP wires to RJ31X terminals 1 (grey) and 8 (brown) respectively.

e.Wire the flying leads of a Direct Connect Cord to the control’s phone terminals as shown in the diagram or plug into the 8-position jack.

f.Plug the Direct Connect Cord into the RJ31X jack.

 

 

 

 

INCOMING

 

 

 

 

PHONE LINE

 

 

 

 

RING

 

 

 

 

TIP

RED

4

5

 

GREEN

 

3

 

6

TO

 

 

 

 

 

RJ31X

 

PREMISES PHONES

 

 

 

 

RING

 

2

 

7

TIP

GREY

1

 

8

BROWN

 

 

DIRECT

 

 

CONNECT

 

 

CORD

 

OR

GREEN

RED

BROWN

GREY

 

 

 

 

 

8-POSITION

TIP

RING

TIP

RING

JACK

} }

 

INCOMING

 

TO

 

PHONE LINE

PREMISES

 

 

 

PHONES

 

01000-008-V0

Full Line Seizure Connections

UL

Do not remove the local sounder shorting jumper (shunt).

External sounders and powerline carrier devices have not been evaluated by UL

 

LOCAL SOUNDER DISABLE: The Master Keypad’s built-in piezo sounder can be disabled by removing the

 

shorting jumper (shunt) on the terminal board. If disabled, however, no sounding will occur upon AC loss,

 

since the external sounder does not operate when AC power is lost.

3.Make External Sounder Connections - The control panel supports either a 6-14VDC piezo sounder (30mA max.) or 6-14VDC bell (120mA max.; e.g. ADEMCO WAVE2EX).

a.Connect a piezo sounder to terminals 10 (+) and 11 (–); OR a bell to terminals 11 (–) and 12 (+).

4.Disable Local Sounder Option - If required the Master Keypad’s built-in piezo sounder can be disabled.

a.Remove the shorting jumper (shunt) on the terminal board.

5.Make Powerline Carrier Device Connections - The control panel supports up to 8 Powerline Carrier Devices. If using these devices, they must be connected to the K10145X10 transformer, as shown in the SUMMARY OF CONNECTIONS diagram.

a.Connect the com/data/sync/ lines from the transformer to terminals 9, 13, and 14, respectively.

If not using the supplied connection cable, you may need to reverse the black and yellow wire connections. Refer to the 80 Device Programming Menu Mode section for details on programming Powerline Carrier Devices.

- 7 -