Wiring Connections
1.Make Earth Ground Connection - The designated earth ground terminal (1) must be terminated in a good earth ground for the lightning transient protective devices in this product to be effective. The following are examples of good earth grounds available at most installations:
Metal Cold Water Pipe - Secure a
AC Power Outlet Ground - Available from
a. Connect terminal 1 to a good earth ground.
2.Make Phone Line Connections - For local or full line seizure proceed to the appropriate steps below.
Local Seizure
a.Connect the incoming phone line to either the
b.Connect the handset phone lines to either the RJ11 jack or terminals 4 (TIP) and 5 (RING).
Full Line Seizure: The control must be placed in series with the incoming phone line. Plugging the Direct Connect Cord directly into the RJ31X jack, allows the control to seize the phone line when an alarm occurs and normal phone line usage by the premises phones if the plug needs to be removed.
c.Cut the incoming RING and TIP phone lines (typically red and green, respectively) and connect them to RJ31X terminals 4 (red) and 5 (green).
d.Connect the premises end of the cut RING and TIP wires to RJ31X terminals 1 (grey) and 8 (brown) respectively.
e.Wire the flying leads of a Direct Connect Cord to the control’s phone terminals as shown in the diagram or plug into the
f.Plug the Direct Connect Cord into the RJ31X jack.
|
|
|
| INCOMING |
|
|
|
| PHONE LINE |
|
|
|
| RING |
|
|
|
| TIP |
RED | 4 | 5 |
| GREEN |
| 3 |
| 6 | TO |
|
|
|
| |
| RJ31X |
| PREMISES PHONES | |
|
|
|
| RING |
| 2 |
| 7 | TIP |
GREY | 1 |
| 8 | BROWN |
|
| DIRECT | ||
|
| CONNECT | ||
|
| CORD |
|
OR
GREEN | RED | BROWN | GREY |
|
|
|
|
| |
TIP | RING | TIP | RING | JACK |
} } |
| |||
INCOMING |
| TO |
| |
PHONE LINE | PREMISES |
| ||
|
| PHONES |
|
Full Line Seizure Connections
UL | Do not remove the local sounder shorting jumper (shunt). |
External sounders and powerline carrier devices have not been evaluated by UL | |
| LOCAL SOUNDER DISABLE: The Master Keypad’s |
| shorting jumper (shunt) on the terminal board. If disabled, however, no sounding will occur upon AC loss, |
| since the external sounder does not operate when AC power is lost. |
3.Make External Sounder Connections - The control panel supports either a
a.Connect a piezo sounder to terminals 10 (+) and 11
4.Disable Local Sounder Option - If required the Master Keypad’s
a.Remove the shorting jumper (shunt) on the terminal board.
5.Make Powerline Carrier Device Connections - The control panel supports up to 8 Powerline Carrier Devices. If using these devices, they must be connected to the K10145X10 transformer, as shown in the SUMMARY OF CONNECTIONS diagram.
a.Connect the com/data/sync/ lines from the transformer to terminals 9, 13, and 14, respectively.
If not using the supplied connection cable, you may need to reverse the black and yellow wire connections. Refer to the ✻80 Device Programming Menu Mode section for details on programming Powerline Carrier Devices.
- 7 -