Honeywell K14114 3/06 Rev.B Programming Default Tables, LYNXR-IInstallation and Setup Guide

Models: K14114 3/06 Rev.B

1 72
Download 72 pages 35.87 Kb
Page 64
Image 64
Manual background

LYNXR-I Installation and Setup Guide

Programming Default Tables

56 ZONE ASSIGNMENT/ALARM REPORT CODES FOR TABLES 3 & 4

Zone No.

Zone Type

Alarm Code

Input Type

Loop Number

 

Zone Descriptor

2

1

1,0

3 (RF)

2

47, 04 (FRONT DOOR)

3

1

1,0

3 (RF)

2

33, 04 (BACK DOOR)

4

3

1,0

3 (RF)

2

80

(WINDOW)

5

3

1,0

3 (RF)

2

80

(WINDOW)

6

3

1,0

3 (RF)

2

80

(WINDOW)

7

3

1,0

3 (RF)

2

80

(WINDOW)

8

10

1,0

3 (RF)

1

56

(MOTION DETECTOR)

9

9

1,0

3 (RF)

1

22, 02 (SMOKE DETECTOR)

26

21

1,0

5 (BR)

3

 

 

27

22

1,0

5 (BR)

2

 

 

28

23

0,0

5 (BR)

4

 

 

29

23

0,0

5 (BR)

1

 

 

30

21

1,0

5 (BR)

3

 

 

31

22

1,0

5 (BR)

2

 

 

32

23

0,0

5 (BR)

4

 

 

33

23

0,0

5 (BR)

1

 

 

92

---

1,0

---

---

 

 

99

6

1,0

---

---

 

 

NOTE: Zone 2 to 41 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic

80 DEFAULT TABLE: APPLIES TO DEFAULT TABLE 4 (devices 2-7 have no default values)

 

 

 

Start

 

 

Stop

 

 

 

 

Zone Type

Restore of

Zone type

Device Number

Action

Event

Zone List

System Operation

Zone List

System operation

1

2

2

1

 

2

 

8**

2

 

 

33

 

36

**NOTE: If using an X10 Powerhouse Security SH10A siren as device 8, you must change the device action default to “3” if using default table 4.

80 DEFAULT TABLE: APPLIES TO DEFAULT TABLE 1 and 2 (devices 1-7 have no default values)

 

 

 

Start

 

 

Stop

 

 

 

 

Zone Type

Restore of

Zone type

Device Number

Action

Event

Zone List

System Operation

Zone List

System operation

8**

2

 

 

33

 

36

81 ZONE LIST FOR OUTPUT DEVICES DEFAULT TABLE: Applies To Default Table 1 - 4.

Zone List 1

28, 32

Zone List 2

29, 33

Zone List 3

2, 3

- 64 -