LYNXR-I Installation and Setup Guide

 

 

 

 

 

Data Field Descriptions

 

 

 

 

 

 

 

34

Exit Delay

 

 

The system will wait the time entered before sounding an

 

00-99 = exit delay time in seconds

alarm if the exit door is left open after the system has been

 

 

 

 

 

 

 

armed.

 

 

 

 

 

UL installations: must be set for a maximum of 60 seconds

 

 

 

 

 

 

 

35

Entry Delay 01

 

 

The system will wait the time entered before sounding alarm upon

 

00-99 = entry delay time in seconds.

entering if system is not disarmed. UL installations: must be set for a

 

 

maximum of 45 seconds

 

 

 

 

 

 

 

 

 

 

 

 

36

Entry Delay 02

 

 

The system will wait the time entered before sounding alarm

 

00-99 = entry delay time in seconds.

upon entering.

 

 

 

 

 

 

 

UL installations: must be set for a maximum of 45 seconds

 

 

 

 

 

37

Audible Exit Warning/Quick Exit

Exit Warning: Sound consists of slow continuous beeps until

 

Exit Warning

 

Quick Exit

last 5 seconds, when it changes to fast beeps. The warning

 

 

 

 

 

sound will end at the termination of exit delay.

 

 

0 = no exit warning

 

0 = no quick

 

 

 

Quick Exit: If enabled, user can restart the exit delay time after

 

 

sound

 

exit

 

 

 

arming in STAY mode by entering the user code and pressing

 

 

1 = provide exit

 

1 = allow quick

 

 

 

the STAY key, or by pressing the STAY key if Quick Arm is

 

 

warning sound

 

exit

enabled. This avoids having the user disarm then re-arm the

 

 

when armed AWAY

 

 

 

 

 

 

system after allowing someone to enter or exit

 

 

 

 

 

 

 

 

 

 

38

Confirmation of Arming Ding

Confirmation of arming is provided by a 1/2 second external sounder

 

0 = no ding

 

 

“ding” that sounds when closing report is sent, or at the end of exit delay.

 

 

 

 

 

 

 

1 = confirmation ding after arming system

If Option 2 is selected the external sounder “ding” occurs immediately

 

 

2 = confirmation ding after arming from RF button or RF

 

 

after the system receives the RF transmission.

 

 

keypad only

 

 

 

 

 

 

 

 

 

 

 

 

39

Power Up In Previous State

When the system powers up armed, an alarm will occur 1

 

0 = always power up in a disarmed state

minute after arming if a zone is faulted, and any bypassed

 

 

 

 

1 = assume the system status prior to power-down

zones will be unbypassed.

 

 

 

 

 

Note: If the previous state was armed AWAY or STAY, the

 

 

 

 

 

system will not respond to sensor changes for 1 minute,

 

 

 

 

 

which allows time for sensors such as PIRs to stabilize.

 

 

 

 

 

UL installations: must be 1 (power up in previous state)

 

 

 

 

 

 

DIALER PROGRAMMING (40–50)

Fields 40, 41, 42: Enter up to the number of digits shown. Enter 0–9, # + 11 for ‘*’; # + 12 for ‘#’; # + 13 for a pause (2 seconds)

NOTE: Whenever AAV is used, primary (field 41) and secondary (field 42) phone numbers should be preceded with the call waiting disable command. Otherwise, there is the possibility of connection of the third party to LYNXR-I during AAV mode.

40

PABX Access Code

If fewer than 6 digits need to be entered, exit by pressing [].

Enter up to 6 digits if PABX is needed to access an

To clear entries from field, press 40.

 

outside line.

 

 

 

 

41

Primary Phone No.

If fewer than 20 digits entered, exit by pressing []. To clear

Enter up to 20 digits.

entries from field, press 41.

 

 

Note: Backup reporting (8 attempts are made to the secondary

 

 

phone number if no kissoff is received after 8 attempts to

 

 

the primary number) is automatic only if there is a

 

 

secondary phone number (field 42).

 

 

 

42

Secondary Phone No.

If fewer than 24 digits entered, exit by pressing []. To clear

Enter up to 24 digits.

entries from field, press 42. See backup reporting note for

 

 

field 41. If using the paging feature, enter the pager phone

 

 

number here.

- 21 -

Page 21
Image 21