Honeywell K14114 3/06 Rev.B Data Field Descriptions, LYNXR-IInstallation and Setup Guide, Device

Models: K14114 3/06 Rev.B

1 72
Download 72 pages 35.87 Kb
Page 23
Image 23

 

 

 

 

 

 

 

 

LYNXR-I Installation and Setup Guide

 

 

 

 

 

 

 

 

 

Data Field Descriptions

 

 

 

 

 

 

 

 

 

 

49

 

Split/Dual Reporting

 

 

This field is used to select a reporting option as follows:

 

 

 

 

 

 

 

 

Enter: 0 - 5 when reporting to telephone receivers.

 

To Primary

 

 

To Secondary

 

 

 

 

 

 

 

 

6 - 9 when reporting to a pager is desired.

 

 

 

 

0 = All reports

 

 

None, unless primary

 

 

 

 

 

 

 

 

10 - 13 when reporting to an auxiliary telephone receiver.

 

 

 

 

 

 

 

fails, then all

 

 

 

 

 

 

 

 

 

Pager Report Format

 

 

 

 

1 = Alarms, Restore, Cancel

 

 

Others

 

 

 

 

 

2 = All except Open/Close, Test

 

Open/Close, Test

 

Options 6-9 send reports to the primary phone number, in a

 

 

 

 

3 = Alarms, Restore, Cancel

 

 

All

 

format defined in Field 48, and send reports to a pager, which

 

 

 

 

4 = All except Open/Close, Test

 

All

 

has its phone number entered as the secondary phone number in

 

 

 

 

5 = All reports

 

 

All

 

Field 42. The pager report is a 7-digit code, with optional 16-

 

 

 

 

To Primary

 

 

To Paging Number

 

digit prefix, in the following format:

 

 

 

 

6 = All reports except Open/Close

 

Alarms, Open/Close ,

 

AAAAAAAAAAAAAAAA-EEE–0NNN where:

 

 

 

 

 

 

 

Troubles

 

AAA = Optional 16 digits for PIN number, etc. See Field 88 for

 

 

 

 

7 = All reports

 

 

Alarms, Troubles

 

full description of these characters.

 

 

 

 

8 = All reports

 

 

Alarms, Open/Close ,

 

EEE = 3-digit Event Code as follows:

 

 

 

 

 

 

 

Troubles

 

911 = Alarm (NN = zone number)

 

 

 

 

9 = All reports except Open/Close

 

Open/Close

 

101 = Open, system disarmed (NN = user no.)

 

 

 

 

 

 

 

 

 

102 = Close, system armed (NN = user no.)

 

 

 

 

To Primary

 

 

To Follow Me System

 

811 = Trouble (NN = zone no.)

 

 

 

 

 

 

 

Phone Number

 

0 = Always displayed before 3-digit user/zone no.

 

 

 

 

10=All reports except Open/Close

 

Alarms, Open/Close ,

 

NNN = 3-digit user number or zone number, depending on the

 

 

 

 

 

 

 

Troubles

 

type of event (EEE) that occurred.

 

 

 

 

11 = All reports

 

 

Alarms, Troubles

 

Follow Me System Report Format

 

 

 

 

12=All reports

 

 

Alarms, Open/Close ,

 

 

 

 

 

 

 

 

Options 10-13 send reports to the primary phone number, in a

 

 

 

 

 

 

 

Troubles

 

format defined in Field 48, and sends voice message to the

 

 

 

 

13=All reports except Open/Close

 

Open/Close

 

secondary phone number entered in Field 42.

 

 

 

 

Will report Users 0, 5-8, and, if using wireless button-type

The message is a repeatable system status announcement. If the

 

 

 

 

devices, will report the zone number of the arm or disarm

manual paging option has been programmed in Field 87, the

 

 

 

 

message will repeat “system, system…..”.

 

 

 

 

button 26-33. All other zones and users are not reported.

 

 

 

 

The message can be terminated by pressing any key on the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

telephone keypad.

 

 

 

 

 

 

 

 

50

 

15-Second Dialer Delay (Burglary)

If enabled, provides delay of burglary report to the central station,

 

 

 

0 = no dialer delay

 

 

 

 

and allows time for the subscriber to avoid a false alarm

 

 

 

 

 

 

 

 

 

 

 

 

1 = provide 15-second delay of burglary alarm report

transmission. The delay applies only to zone type 3 and 5 alarms

 

 

 

 

when armed away

 

 

 

 

and not to zone type 24 alarms (silent burglary) or to 24-hour zone

 

 

 

 

 

 

 

 

 

types 6, 7, and 8 (silent panic, audible alarm, auxiliary alarm),

 

 

 

 

 

 

 

 

 

which are always sent as soon as they occur.

 

 

 

 

 

 

 

 

 

UL installations: must be 0 (no delay)

 

 

 

 

 

 

 

 

 

 

51

 

Periodic Test Report

 

 

Test report code entered in field 64 is sent.

 

 

 

0 = no test report

2 = weekly

 

 

 

 

 

 

 

 

 

 

1 = once every 24 hrs

3 = once every 30 days

 

 

 

 

 

 

 

 

 

 

 

52

 

First test Report Offset

 

 

Select the time for the first report following programming or

 

 

 

0 = 24 hrs after exit program mode or download

downloading.

 

 

 

 

 

 

 

 

1 = 6 hours after exit program mode or download

 

 

 

 

 

2 = 12 hrs after exit program mode or download

 

 

 

 

 

3 = 18 hrs after exit program mode or download

 

 

 

 

 

 

 

 

 

53

 

Sescoa/Radionics Select

If disabled, selects Radionics, which uses hexadecimal 0-9, B-F

 

 

 

 

0 = Radionics (0–9, B–F reporting)

reporting.

 

 

 

 

1 = SESCOA (0–9 only reporting)

If enabled, selects Sescoa, which uses only numeric reporting (0-9).

 

 

 

 

 

 

 

 

 

Select 0 for all other formats.

 

 

 

 

 

 

 

 

54

 

Lack of Usage Notification

If enabled, notifies the central station if an end user is not

 

 

 

0 = Disabled

4 = 90 days

operating their security system by sending a System Inactivity

 

 

 

 

 

 

 

 

1 = 1 day

5 = 180 days

report 654. The report will be sent only to the Primary phone

 

 

 

 

2 = 7 days

6 = 365 days

number and only if Contact ID® format was selected.

 

 

 

 

3 = 27 days

 

 

 

 

Note: The report will follow the 49 = 0 rules, no matter which

 

 

 

 

Note: There is no local annunciation indicating that this

selection was made in 49.

 

 

 

 

report has been sent to the Central Station.

 

 

 

 

 

 

 

 

 

55

 

Enable/Disable LRR/IP Communications

This option is used to enable/disable Central Station reporting via

 

 

 

Device

 

 

 

 

the LRR/IP Communications Device (See Field *77). Upload/

 

 

 

 

 

 

 

 

 

 

 

 

0 = disable

 

 

 

 

download via the Internet IP module is not affected by this entry.

 

 

 

 

 

 

 

 

Zone 103 supports the LRR/IP Communications Device.

 

 

 

 

1 = enable

 

 

 

 

 

 

 

 

 

 

 

 

Notes: (1) When LYNXR-I is in programming mode it will not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

communicate with the LRR/IP device. As a result the

 

 

 

 

 

 

 

 

 

LRR/IP device will transmit 355 (event and restore)

 

 

 

 

 

 

 

 

 

reports to the Central Station.

 

 

 

 

 

 

 

 

 

(2) Zone 103 can not be bypassed.

 

 

 

 

 

 

 

 

 

 

 

- 23 -

Page 23
Image 23
Honeywell K14114 3/06 Rev.B Data Field Descriptions, LYNXR-IInstallation and Setup Guide, Split/Dual Reporting, Device