Honeywell K14114 3/06 Rev.B Delete serial number, Enhanced Sequential Mode, Serial number

Models: K14114 3/06 Rev.B

1 72
Download 72 pages 35.87 Kb
Page 40
Image 40
Delete serial number

LYNXR-I Installation and Setup Guide

 

83 Enhanced Sequential Mode

 

 

 

 

 

 

 

 

Serial number

This prompt can be used to enroll the transmitter serial number via

 

Ib

zz

 

Enter transmitter’s 7- digit serial number via RF

RF transmission or manually. If using the RF Learning Mode there

 

 

is no need to manually enter a serial number. Proceed directly to RF

 

 

learning or manually.

Learning. Upon entering the Serial Number mode, the Zone

 

 

 

 

 

 

 

[#] = return to (1A) prompt and reject whatever

Descriptors will be announced.

 

 

 

 

serial number entries have been made.

Note: BR type devices can be enrolled only by transmission from BR

 

Ib

 

 

[] = return to (1A) prompt (if a valid serial

devices. Likewise, UR and RF devices can only be enrolled by

 

 

 

number has been enrolled, “L” is displayed

transmission from a UR or RF device

 

 

 

 

 

 

 

 

and the serial number will be copied into

RF Learning - Two (2) transmissions (2 key depressions) at least

 

 

 

 

 

 

 

EEROM and the last serial entered buffer.

five seconds apart, will be required for BR type or four (4)

 

 

 

 

 

transmissions (fault, restore and fault, restore) for UR or RF type. If

 

 

 

 

Note: For zones 26, 30, 34 and 38 only BR type

the learned serial number has a different loop number than that

 

 

 

 

entered in 56 the system will announce the Voice Descriptor, if it

 

 

 

 

devices can be used.

 

 

 

 

is programmed, followed by two beeps and will return to Prompt (1A)

 

 

 

 

 

 

 

 

 

 

and “L” will be displayed.

 

 

 

 

 

If the loop number captured by RF transmission and that entered in

 

 

 

 

 

56 mode match, the system will announce the Voice Descriptor, if it

 

 

 

 

 

is programmed, followed by three beeps and return to Prompt (1A)

 

 

 

 

 

and “LC” will be displayed. No additional transmissions are needed

 

 

 

 

 

for confirmation.

 

 

 

 

 

Manual Entry - Enter the 7-digit serial number printed on the

 

 

 

 

 

transmitter. If you enter an incorrect digit, press the [#] key to

 

 

 

 

 

backup to prompt (1A) and start over. When all 7 digits are entered,

 

 

 

 

 

press the [] key. If less than 7 digits are entered, the keypad will

 

 

 

 

 

emit a single long beep and return to the (1A) prompt without

 

 

 

 

 

displaying the “L”.

 

 

 

 

 

If more than 7 digits have been entered, the first 6 digits will be

 

 

 

 

 

saved along with the last digit that was entered (entering 123456789

 

 

 

 

 

yields the serial number 1234569).

 

 

 

 

 

Note: If 52 seconds pass and no entry has been made, the system

 

 

 

 

 

returns to prompt (1A).

 

 

 

 

 

 

 

 

 

 

Delete serial number

This function deletes only the serial number.

 

F

 

 

 

 

0 = discard the delete request

Entering a “9” at prompt (1A). Confirmation of the delete request will

 

 

 

1 = confirm requested delete

cause deletion of the serial number pertaining to the zone being

 

 

 

 

Note: Entering a “9” at prompt (1A) will cause the

programmed.

 

 

 

 

 

 

 

 

 

panel to return to prompt (1A) regardless of the

 

 

 

 

 

confirmation answer.

 

 

 

 

 

 

 

Note: In Enhanced Sequential Learn Mode, 4 button type keys will always be learned simultaneously. They will be stopped at the 4 button boundaries of 26, 30, 34 and 38, provided the zone is free of a serial number. If the first zone of the key has a serial number learned, the remaining keys cannot be programmed in sequential learn mode. In addition, if the zone has not been set up (duplicate loop, missing zone type, etc.) only entries 0 (skip to the next zone) and 4 (copy the key template) will be allowed.

- 40 -

Page 40
Image 40
Honeywell K14114 3/06 Rev.B setup guide Delete serial number, Enhanced Sequential Mode, LYNXR-IInstallation and Setup Guide