Honeywell K14114 3/06 Rev.B Device Programming Menu Mode, LYNXR-IInstallation and Setup Guide

Models: K14114 3/06 Rev.B

1 72
Download 72 pages 35.87 Kb
Page 36
Image 36
Powerline Carrier Device

LYNXR-I Installation and Setup Guide

80 Device Programming Menu Mode

The following explains these prompts in detail. The left two columns identify the prompts and list the available entries. The right-most column provides a further explanation of the entries.

Note: Entering a number other than one specified will give unpredictable results.

 

 

 

 

Powerline Carrier Device

Entering “1” advances to the next prompt below.

 

 

 

80

 

programming

 

Entering “0” exits mode, upon which this prompt blinks, indicating

 

 

 

 

the mode is inactive.

 

 

 

 

 

0 = exit mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 = enter mode

 

 

 

 

 

 

 

 

 

Device number

 

Enter device numbers as 2-digit entries.

 

 

A

0I

 

 

 

 

01-08 = device number to be programmed

 

 

 

 

 

 

[] = continue

 

 

 

 

 

 

 

 

 

00 = exit Device Programming mode

 

 

 

 

 

 

 

 

Device action

 

Enter the 1-digit action (0-3) for the device being programmed

 

b

aa

 

0 = No response

 

(current action is displayed).

 

 

 

 

NOTES:

 

 

 

 

 

1 = Close for 2 seconds

 

 

 

 

 

 

 

2 = Close and Stay Closed

1. If “3” is entered (pulse), only up to 3 different devices can be

 

 

 

 

 

 

 

 

pulsed if one of the devices is a siren/horn (X10 Powerhouse

 

 

 

 

3 = Continuous Pulse on & off (1 sec ON, 1 sec

 

 

 

 

Security model SH10A). In addition, the siren/horn cannot be

 

 

 

 

OFF)

 

manually activated using the lights on/lights off keypad

 

 

 

 

[] = continue

 

commands.

 

 

 

 

 

 

 

[#] = return to previous prompt

2. If using an X10 Powerhouse Security SH10A siren:

 

 

 

 

 

 

• you must use device action “3.”

 

 

 

 

 

 

 

• you must change the device action default to “3” if using default

 

 

 

 

 

 

table 2 or 4

 

 

 

 

 

 

 

Start event type

 

Enter the 1-digit event type (0-3) to activate the device being

 

C

et

 

0 = Not used

3 = Trouble

programmed. A zone list must be used in conjunction with an event. If

 

 

a zone type/system operation is to be used instead of an event, enter

 

 

1 = Alarm

[] = continue

 

 

“0”.

 

 

 

 

 

 

 

 

 

 

 

 

 

2 = Fault

[#] = return to previous

 

 

 

 

 

 

 

 

 

prompt

 

 

 

 

 

 

 

 

Start zone list

 

If a zone list will be used to start the device action, enter the zone list

 

d

zl

 

1-3 = zone list number (to be programmed in

number at this prompt.

 

 

 

 

 

 

 

 

 

 

field 81)

 

 

 

 

 

 

 

 

 

0 = zone list not used for this device

 

 

 

 

 

 

 

 

[] = continue

 

 

 

 

 

 

 

 

 

[#] = return to previous prompt

 

 

 

 

 

 

 

 

Start zone type

 

If a zone type or system operation will be used to start the device

 

E

 

 

 

zt

 

01-58 = zone type to start this device action

action, enter the appropriate 2-digit code for the device being

 

 

(select only those that are applicable)

programmed (see table that follows).

 

 

 

 

 

00 = zone type not used for this device

 

Choices for zone types

 

 

 

 

 

[] = continue

 

00 = Not Used

04 = Interior Follower

08 = 24 Hr Aux

 

 

 

 

[#] = return to previous prompt

01 = Entry/Exit #1 05 = Trouble Day/Alarm Night

09 = Fire

 

 

 

 

 

 

02 = Entry/Exit #2

06 = 24 Hr Silent

10 = Interior w/Delay

 

 

 

 

 

 

03 = Perimeter

07 = 24 Hr Audible

24 = Silent Burglary

 

 

 

 

 

 

Choices for system operation

 

 

 

 

 

 

20 = Arming–Stay

 

33 = Any Alarm (except

42 = Sys. Batt. Low

 

 

 

 

 

 

 

 

zt 08 & 09)

 

 

 

 

 

 

 

21 = Arming–Away

36 = At Bell Timeout**

43 = Comm. Failure

 

 

 

 

 

 

22 = Disarm. (Code

38 = Chime

52 = Kissoff

 

 

 

 

 

 

+ OFF)

 

 

 

 

 

 

 

 

 

31 = End of Exit

 

39 = Any Fire Alarm

58 = Duress

 

 

 

 

 

 

Time

 

 

 

 

 

 

 

 

 

32 = Start of Entry

 

40 = Bypassing

 

 

 

 

 

 

 

Time

 

 

 

 

 

 

 

 

 

** Or at Disarming (which ever occurs earlier)

 

 

 

 

 

Stop zone list

 

If a zone list will be used to STOP, or restore, the device action, enter

 

F

zl

 

1-3 = zone list to stop this device action

the zone list number 1, 2, or 3 (to be programmed in 81 mode). If not

 

 

used, enter “0”.

 

 

 

 

 

0 = zone list not used

 

 

 

 

 

 

 

 

[] = continue

 

 

 

 

 

 

 

 

 

[#] = return to previous prompt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop zone type

 

If a zone type or system operation will be used to STOP the device

 

IA

zt

 

01-58 = zone type to start this device action

action, enter the appropriate 2-digit code (see the "ZT" choices listed

 

 

above). If not, enter 00.

 

 

 

 

(select only those that are applicable)

 

 

 

 

The display then returns to the DEVICE NUMBER prompt (A) so

 

 

 

 

 

 

 

00 = zone type not used for this device

that you can enter the next device number to be programmed, or enter

 

 

 

 

[] = continue

 

 

 

 

 

 

[0][0] to end device programming.

 

 

 

 

 

[#] = return to previous prompt

 

 

 

 

- 36 -

Page 36
Image 36
Honeywell K14114 3/06 Rev.B Device Programming Menu Mode, LYNXR-IInstallation and Setup Guide, Powerline Carrier Device