CLEARANCES TO COMBUSTIBLES

Clearances may only be reduced by means approved by the regulatory authority. It is very important to follow minimum clearances for chimney connectors to combustibles such as walls and ceilings when installing the stove near non-combustible surfaces.

 

 

 

K

D

C

B

J H

 

 

 

I

A

 

 

H

E

 

 

 

G

 

 

 

Tribute Clearances

 

Parallel

Corner

Clearances (inches)

A

B

C

D

E

 

G

H

I

J

K

Single wall stove pipe without heat shield

16.5

19

21

24

27.5

 

13

17

25.5

28.5

68.25

Single wall stove pipe with heat shield

16.5

14.5

16.5

19.5

27.5

 

13

11

19.5

22.5

59.75

Double wall stove pipe with heat shield

16.5

8

10

13

27.5

 

13

7

15.5

18.5

54

HearthStone Quality Home Heating Products Inc ®

8

Tribute Model 8040

 

 

Page 9
Image 9
Hearth and Home Technologies 8040 04-28-04 owner manual Tribute Clearances Parallel Corner Clearances inches