B. Intellifire Ignition System

Symptom

Possible Cause

Corrective Action

 

 

 

1. Pilot won’t light. The

A. Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are

ignitor/module makes

 

connected to correct terminals on module and pilot assembly.

noise, but no spark.

 

 

 

B. Loose connections or electrical

Verify no loose connections or electrical shorts in wiring from module

 

shorts in the wiring.

to pilot assembly. Verify connections underneath pilot assembly are

 

 

tight; also verify connections are not grounding out to metal chassis,

 

 

pilot burner, pilot enclosure, mesh screen if present, or any other

 

 

metal object.

 

 

 

 

C. Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be

 

 

approximately .17 inch or 1/8 in. (3 mm).

 

D. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place a grounded wire about 3/16 in.

 

 

(5 mm) away from “I” terminal on module. Place ON/OFF rocker

 

 

switch or wall switch in ON position. If there is no spark at “I” terminal

 

 

module must be replaced. If there is a spark at “I” terminal, module

 

 

is fine. Inspect pilot assembly for shorted sparker wire or cracked

 

 

insulator around electrode. Replace pilot if necessary.

 

 

 

2. Pilot won’t light, there is no

A. No power or transformer

Verify that transformer is installed and plugged into module. Check

noise or spark.

installed incorrectly.

voltage of transformer under load at spade connection on module

 

 

with ON/OFF switch in ON position. Acceptable readings of a good

 

 

transformer are between 3.2 and 2.8 volts AC.

 

 

 

 

B. A shorted or loose connection

Remove and reinstall the wiring harness that plugs into module.

 

in wiring configuration or wiring

Verify there is a tight fit. Verify pilot assembly wiring to module.

 

harness.

Remove and verify continuity of each wire in wiring harness. Replace

 

 

any damaged components.

 

 

 

 

C. Improper wall switch wiring.

Verify that 110/VAC power is “ON” to junction box.

 

 

 

 

D. Module not grounded.

Verify black ground wire from module wire harness is grounded to

 

 

metal chassis of appliance.

 

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF rocker switch or wall

 

 

switch in ON position. If there is no spark at “I” terminal module must

 

 

be replaced. If there is a spark at “I” terminal, module is fine. Inspect

 

 

pilot assembly for shorted sparker wire or cracked insulator around

 

 

electrode.

 

 

 

3. Pilot sparks, but Pilot will

A. Gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet

not light.

 

pressure reading is within acceptable limits, inlet pressure must not

 

 

exceed 14 in. W.C.

 

B. Ignitor gap is incorrect.

Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in (3

 

 

mm).

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

 

 

D. Module voltage output / Valve/

Verify battery voltage is at least 2.7 volts. Replace batteries if voltage

 

Pilot solenoid ohms readings.

is below 2.7.

 

 

 

Heatilator • BCBV36 • 4008-033 • Rev F • 12/08

35

Page 35
Image 35
Hearth and Home Technologies BCBV36I owner manual Intellifire Ignition System, Symptom Possible Cause Corrective Action

BCBV36I, BCBV36 specifications

Hearth and Home Technologies is a leader in delivering innovative heating solutions, and their BCBV36 and BCBV36I models demonstrate this commitment to quality and performance. These versatile fireplaces are designed to provide warmth, ambiance, and a modern aesthetic that complements various home styles.

The BCBV36 and BCBV36I models are built with efficiency and functionality in mind. They feature a clean-burning, vented gas design that produces realistic flames while maximizing heat output. With an impressive heating capacity, these fireplaces can effectively warm large living spaces, making them an ideal choice for homeowners looking to enhance their comfort and ambiance during the colder months.

One of the standout characteristics of the BCBV36 and BCBV36I is their customizable appearance. These models come with several decorative options, allowing users to choose from various logs, stones, and glass media to create the perfect centerpiece for their living area. The sleek design of the fireplace ensures that it fits seamlessly into any room, while the large viewing area offers an unobstructed view of the flames.

In terms of technology, both models are equipped with advanced electronic ignition systems for ease of use and reliability. The user-friendly control panel allows homeowners to adjust the flame height and heat output conveniently, enhancing the overall user experience. Additionally, the fireplaces can be integrated with remote control options for added convenience.

Safety is a critical aspect of any heating solution, and the BCBV36 and BCBV36I incorporate several features to ensure peace of mind. The built-in safety shut-off system eliminates risks associated with overheating while the heat exchanger design maximizes warmth while minimizing exhaust emissions.

Maintenance is also simplified with these models. The easy-to-remove glass fronts make it straightforward for homeowners to clean and maintain the fireplace, ensuring it remains a stunning focal point in the home.

In summary, the Hearth and Home Technologies BCBV36 and BCBV36I offer an exceptional blend of style, efficiency, and safety. With modern designs, customizable options, and advanced technology, these fireplaces are a fantastic investment for anyone looking to enhance their home’s atmosphere and heating capabilities. These qualities make them a top choice in the realm of residential gas fireplaces.