Hearth and Home Technologies BCBV36 Pilot lights but continues Shorted or loose connection

Models: BCBV36I BCBV36

1 44
Download 44 pages 56.21 Kb
Page 36
Image 36

B. Intellifire Ignition System (continued)

4. Pilot lights but continues

A. A shorted or loose connection

Verify all connections to wiring diagram in manual. Verify connections

to spark, and main burner

in flame sensing rod.

underneath pilot assembly are tight. Verify connections are not

will not ignite. (If the pilot

 

grounding out to metal chassis, pilot burner, pilot enclosure or screen

continues to spark after

 

if present, or any other metal object.

the pilot flame has been lit,

 

 

flame rectification has not

 

 

B. Poor flame rectification or

With fixed glass assembly in place, verify that flame is engulfing

occurred.)

contaminated flame sensing

flame sensing rod on left side of pilot hood. Flame sensing rod

 

 

rod.

should glow shortly after ignition. Verify correct pilot orifice is

 

 

installed and gas inlet is set to pressure specifications. Clean flame

 

 

sensing rod with emery cloth to remove any contaminants that may

 

 

have accumulated on flame sensing rod.

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

Verify that wire harness is firmly connected to the module.

 

 

 

 

D. Damaged pilot assembly or

Verify that ceramic insulator around the flame sensing rod is not

 

contaminated flame sensing

cracked, damaged, or loose. Verify connection from flame sensing

 

rod.

rod to white sensor wire. Clean flame sensing rod with emery cloth

 

 

to remove any contaminants that may have accumulated on flame

 

 

sensing rod. Verify continuity with a multimeter with ohms set at

 

 

lowest range. Replace pilot if any damage is detected.

 

 

 

 

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF rocker switch or wall

 

 

switch in ON position. If there is no spark at “I” terminal module must

 

 

be replaced. If there is a spark at “I” terminal, module is fine.

 

 

 

5. The pilot and main

A. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish while in

 

 

B. Improper gas inlet pressure.

Verify with manometer. NG should read 5-14 inches w.c. LP should

operation.

 

read 10-14 inches w.c.

 

 

 

C. Inner vent pipe leaking exhaust

Check venting system for damage. Replace/repair improperly

 

gases back into the system.

assembled pipe sections.

 

 

 

 

D. Glass installed improperly.

Check to ensure glass is installed properly. Replace glass panel

 

 

assembly.

 

E. Improper vent cap installation.

Check for proper installation and freedom from debris or blockage.

 

 

 

 

F. High limit switch has been

This appliance is equipped with an auto reset high limit switch

 

automatically activated.

which will shut down the appliance if it spills under flue blockage or

 

 

excessive negative pressure conditions. Shut off the appliance and

 

 

the gas supply. Do not attempt to operate the appliance until it has

 

 

been examined by a qualified service technician.

 

 

 

36

Heatilator • BCBV36 • 4008-033 • Rev F • 12/08

Page 36
Image 36
Hearth and Home Technologies BCBV36I owner manual Pilot lights but continues Shorted or loose connection

BCBV36I, BCBV36 specifications

Hearth and Home Technologies is a leader in delivering innovative heating solutions, and their BCBV36 and BCBV36I models demonstrate this commitment to quality and performance. These versatile fireplaces are designed to provide warmth, ambiance, and a modern aesthetic that complements various home styles.

The BCBV36 and BCBV36I models are built with efficiency and functionality in mind. They feature a clean-burning, vented gas design that produces realistic flames while maximizing heat output. With an impressive heating capacity, these fireplaces can effectively warm large living spaces, making them an ideal choice for homeowners looking to enhance their comfort and ambiance during the colder months.

One of the standout characteristics of the BCBV36 and BCBV36I is their customizable appearance. These models come with several decorative options, allowing users to choose from various logs, stones, and glass media to create the perfect centerpiece for their living area. The sleek design of the fireplace ensures that it fits seamlessly into any room, while the large viewing area offers an unobstructed view of the flames.

In terms of technology, both models are equipped with advanced electronic ignition systems for ease of use and reliability. The user-friendly control panel allows homeowners to adjust the flame height and heat output conveniently, enhancing the overall user experience. Additionally, the fireplaces can be integrated with remote control options for added convenience.

Safety is a critical aspect of any heating solution, and the BCBV36 and BCBV36I incorporate several features to ensure peace of mind. The built-in safety shut-off system eliminates risks associated with overheating while the heat exchanger design maximizes warmth while minimizing exhaust emissions.

Maintenance is also simplified with these models. The easy-to-remove glass fronts make it straightforward for homeowners to clean and maintain the fireplace, ensuring it remains a stunning focal point in the home.

In summary, the Hearth and Home Technologies BCBV36 and BCBV36I offer an exceptional blend of style, efficiency, and safety. With modern designs, customizable options, and advanced technology, these fireplaces are a fantastic investment for anyone looking to enhance their home’s atmosphere and heating capabilities. These qualities make them a top choice in the realm of residential gas fireplaces.