B. Gas Pressures

C. Gas Connection

Proper input pressures required for optimum appliance per- formance, gas line sizing requirements need to be followed from NFPA51.

WARNING

Fire Risk. Explosion Hazard.

High pressure will damage valve.

• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

• Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

NOTE: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI Z223.1. Instal- lation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.)

NOTE: A listed (and Commonwealth of Massachusetts approved) 1/2 inch (13mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

WARNING

Verify inlet pressures.

High pressure may cause overfire condition.

• Low pressure may cause explosion. Install regulator upstream of valve if line pressure

is greater than 1/2 psig.

WARNING

Gas Leak Risk.

Support control when attaching pipe to prevent bending gas line.

Pressure requirements for appliance are shown in the table below.

PRESSURE

NG

LP

Minimum Inlet Pressure

5 inches w.c.

11 inches w.c.

Maximum Inlet Pressure

10 inches w.c.

13 inches w.c.

Manifold Pressure on “HI”

3.5 inches w.c.

10 inches w.c.

If the pressure is not sufficient, ensure:

1)the piping used is large enough.

2)the supply regulator is adequately adjusted.

3)that the total gas load for the residence does not exceed the amount supplied.

The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the regulator is at an improper pressure.

NOTE: The gap between the supply piping and gas access hole may be plugged with non-combustible insulation to prevent cold air infiltration.

Leak test all gas line joints and the gas control valve prior to and after starting the fireplace.

Before making the gas connection, ensure that the appliance you are installing is designed for the type of gas being supplied. This information can be found on the Ratings Label under the appliance. If the appliance has been converted to propane (LP), the valve cover should have a label stating that the unit has been converted to propane.

Connect the gas line at the 3/8 in. (9.5mm) pipe connector on the valve at the back of appliance. We recommend connecting the appliance with an approved flex gas line. If flex gas lines are not approved in your area, you must connect a hard pipe to the gas hookup.

You must supply a manual shut-off valve in a visible location within 3 feet (914mm) of the appliance.

September 1, 2008

Quadra-Fire · Castile Gas Stove · 7023-111E

Page 25

Page 25
Image 25
Hearth and Home Technologies CASTILE-GAS-MBK, CASTILE-GAS-PMH, CASTILE-GAS-CSB, CASTILE-GAS-CWL Gas Pressures Gas Connection

CASTILE-GAS-CSB, CASTILE-GAS-MBK, CASTILE-GAS-PMH, CASTILE-GAS-CWL specifications

Hearth and Home Technologies (HHT) has made significant strides in the world of gas stoves, offering a range of stylish and efficient options tailored to elevate any living space. Among their impressive lineup are the CASTILE-GAS-CWL, CASTILE-GAS-PMH, CASTILE-GAS-MBK, and CASTILE-GAS-CSB models. Each of these gas stoves combines modern technology with classic design, making them a popular choice for homeowners looking to add warmth and comfort to their homes.

The CASTILE-GAS-CWL features a classic design with elegant lines, making it suitable for both traditional and contemporary spaces. This model comes equipped with a powerful heat exchanger that efficiently distributes warmth throughout the room while maintaining optimal energy consumption. The intuitive control panel allows users to easily adjust the temperature settings and flame height, providing a customized heating experience.

Next, the CASTILE-GAS-PMH model stands out with its sleek and modern aesthetics. With an emphasis on efficiency, this gas stove incorporates advanced combustion technology to ensure cleaner burning and reduced emissions. Its programmable thermostat feature allows for precise temperature control, which can be operated remotely, providing convenience to users. Enhanced safety features, such as an automatic shut-off system, give homeowners peace of mind.

The CASTILE-GAS-MBK model showcases a bold and contemporary design, featuring a large viewing window that allows users to enjoy the mesmerizing flames. Known for its robust build quality, this model is designed to withstand the test of time. The adjustable flame height and remote control operation further enhance user convenience. Additionally, the high-efficiency rating of this model makes it an environmentally friendly choice, reducing the overall carbon footprint.

Finally, the CASTILE-GAS-CSB brings a touch of rustic charm to its design while incorporating advanced heating technologies. This model offers exceptional heat output and a large firebox, ensuring maximum warmth in larger areas. The vent-free technology allows for greater flexibility in installation, enabling homeowners to place it in a variety of locations without the need for external venting systems.

Overall, Hearth and Home Technologies has successfully created a line of gas stoves that blend aesthetic appeal with reliability and efficiency. Each model in the CASTILE range comes equipped with unique features that cater to diverse consumer needs, making them an excellent addition to any home desiring energy-efficient heating solutions. Whether you're looking for classic elegance or modern flair, HHT's CASTILE series has something for everyone.