E36/39/42 INSTALLATION INSTRUCTIONS

D. PRE-INSTALLATION PREPARATION

1. Fireplace Locations and Space Requirements

Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 2.

Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other locations of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of the fireplace. Consideration should be given to these factors before deciding on a location.

CLEARANCES!

A minimum 1/2 in. air clearance must be maintained at the back and sides of the fireplace assembly.

Chimney sections at any level require a 2 in. minimum air space clearance between the framing and chimney section.

Figure 2 - Fireplace Locations

Figures 3 and 4 show two typical installations assuming an outside air kit is being used. Therefore, an allowance must be made for 90-deg bends. Less space is required when ducting goes directly outside without forming elbows.

These are

rough

framing

dimensions

only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cat #

 

A

B

 

 

 

Cat #

A

B

C

 

D

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E/EC36

 

42 in

45 in.

 

 

 

E/EC36

42 in.

72-3/4 in.

36-3/8 in.

 

15-5/8 in.

51-3/8 in.

 

 

1067 mm

1143 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1067 mm

1848 mm

924 mm

 

397 mm

1305 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E/EC39

 

45 in.

48 in.

 

 

 

E/EC39

45 in.

75-3/4 in.

37-7/8 in.

 

16-5/8 in.

53-1/2 in.

 

 

1143 mm

1219 mm

 

 

 

1143mm

1924 mm

962 mm

 

422 mm

1359 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E/EC42

 

48 in.

51 in.

 

 

 

E/EC42

48 in.

78-3/4 in.

39-3/8 in.

 

17-5/8 in.

55-3/8 in.

 

 

1219 mm

1295 mm

 

 

 

1219 mm

2000 mm

1000 mm

 

448 mm

1407 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3

 

 

 

 

 

 

 

Figure 4

 

 

Installation Along a Wall or an Exterior Chase

 

 

 

Corner Installation

 

 

WARNING!

Do not draw outside air from garage spaces. Exhaust products of gasoline engines are hazardous.

Do not install outside air ducts such that the air may be drawn from attic spaces, basements or above the roofing where other heating appliances or fans and chimneys exhaust or utilize air. These precautions will reduce the possibility of fireplace smoking or air flow reversal.

WARNING!

To prevent contact with sagging or loose insulation, the fireplace must not be installed against vapor barriers or exposed insulation. Localized overheating could occur and a fire could result.

10

17335 Rev L

07/04

Page 10
Image 10
Hearth and Home Technologies E36, E39, E42 PRE-INSTALLATION Preparation, Fireplace Locations and Space Requirements