R

M

N

P

Q

(See Note 2)

V

T

VS Electrical S

Service

D*

V

V

V

= VENT TERMINAL

X = AIR SUPPLY INLET

= AREA WHERE TERMINAL IS NOT PERMITTED

A

=

12 inches

clearances above grade, veranda,

L**

=

.7 ft

clearance above paved

 

 

(See Note 1)

porch, deck or balcony

 

 

 

 

(See Note 1)

 

sidewalk or a paved driveway

B

=

12 inches

clearances to window or door

 

 

 

 

 

 

 

 

located on public property

M*** =

18 inches

clearance under veranda, porch,

 

 

 

that may be opened, or to perma-

 

 

 

nently closed window. (Glass)

 

 

 

 

 

 

 

 

deck, balcony or overhang

D*

=

18 inches

vertical clearance to unventilated

 

 

 

 

42 inches

vinyl

 

 

 

 

 

 

soffit or to ventilated soffit located

S

=

 

6 inches

clearance from sides of electri-

 

 

 

above the terminal

 

 

 

 

 

(See Note 5)

 

cal service

 

 

 

 

 

*30 inches

for vinyl clad soffits and below

T

=

12 inches

clearance above electrical

 

 

 

electrical service

 

 

 

 

(See Note 5)

 

service

 

 

 

F

=

9 inches

clearance to outside corner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alcove Applications

 

 

 

 

 

G

=

6 inches

clearance to inside corner

 

 

 

 

 

 

 

 

 

N

 

=

6 inches

non-vinyl sidewalls

 

H

=

3 ft. (Canada)

not to be installed above a gas

 

 

 

 

 

 

 

 

 

12 inches

vinyl sidewalls

 

 

 

 

meter/regulator assembly within 3

 

 

 

 

 

 

 

 

 

 

 

P

 

=

8 ft.

 

 

 

 

 

 

 

 

 

feet (90 cm) horizontally from the

 

 

 

 

 

 

 

 

 

 

 

 

center-line of the regulator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

QMIN

 

RMAX

 

 

I

=

3 ft

clearance to gas service regulator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 cap

 

3 feet

 

2 x Q ACTUAL

 

 

 

 

 

vent outlet

 

 

 

 

 

 

 

 

J

=

9 inches (U.S.A.)

 

 

 

 

 

2 caps

 

6 feet

 

1 x Q ACTUAL

 

 

 

 

12 inches (Canada) clearance to non-mechanical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 caps

 

9 feet

 

2/3 x Q ACTUAL

 

 

 

 

 

air supply inlet to building or the

 

 

 

 

 

 

 

 

 

 

 

combustion air inlet to any other

 

 

 

 

4 caps

 

12 feet

 

1/2 x Q ACTUAL

 

 

 

 

 

appliance

 

 

 

 

 

 

 

 

 

 

 

 

 

K

=

3 ft. (U.S.A.)

 

 

 

QMIN

= # termination caps x 3

RMAX = (2 / # termination caps) x QACTUAL

 

 

 

 

 

 

 

 

 

 

6 ft. (Canada)

clearance to a mechanical (pow-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ered) air supply inlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2.

Note 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap shield is suggested. (See vents components page)

Note 2: Termination in an alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specified for

vinyl or non-vinyl siding and soffits. 1. There must be 3 feet minimum between termination caps. 2. All mechanical air intakes within 10 feet of a termination cap must be a minimum of 3 feet below the termination cap. 3. All gravity air intakes within 3 feet of a termination cap must be a minimum of 1 foot below the termination cap.

Figure 18. Minimum Clearances for Termination

Note 3: Local codes or regulations may require different clearances.

Note 4: Termination caps may be hot. Consider their proximity to doors or other traffic areas.

Note 5: Location of the vent termination must not interfere with access to the electrical service.

WARNING: In the U.S: Vent system termination is NOT permitted in screened porches. You must follow side wall, overhang and ground clearances as stated in the instructions.

In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow all side walls, overhang and ground clearances as stated in the instructions.

Heat & Glo assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.

Heat & Glo • Everest • 750-900 Rev. o • 10/08

20

Page 20
Image 20
Hearth and Home Technologies Everest owner manual Minimum Clearances for Termination

Everest specifications

Hearth and Home Technologies (HHT) is renowned for its commitment to innovation and quality in the hearth industry, and the Everest model exemplifies this ethos. Designed to redefine the traditional fireplace experience, the Everest is a blend of advanced technology, exceptional design, and a focus on user convenience.

One of the main features of the Everest is its impressive heating capacity. The fireplace is engineered to provide substantial warmth, making it ideal for larger spaces. With an output of up to 40,000 BTUs, the Everest can efficiently heat rooms while remaining visually striking. The larger viewing area, framed by a sleek design, offers an unobstructed view of the mesmerizing flames, creating a stunning focal point in any home.

The Everest is equipped with cutting-edge technology, including an advanced combustion system. This system ensures optimal fuel efficiency and reduced emissions, making it an environmentally friendly choice. The High-Definition glow and realistic flame patterns enhance the overall ambiance, providing a realistic fire experience without the hassle of traditional wood burning.

User control is a significant aspect of the Everest's design. It features a user-friendly remote control that allows homeowners to adjust the flame height, heat output, and even the ember bed color, tailoring the ambiance to suit any occasion. Smart home compatibility is another notable characteristic, enabling integration with home automation systems for seamless control.

Durability and craftsmanship are hallmarks of HHT products, and the Everest is no exception. Constructed from high-quality materials, it offers resilience and long-lasting performance. The unit is designed for easy maintenance, with features that simplify cleaning and upkeep, ensuring that it remains a centerpiece of comfort for years to come.

One of the Everest's standout attributes is its versatility in installation. It can be built into various types of structures, whether it's a traditional home or a modern setting, ensuring that it fits seamlessly into any interior design scheme. The customization options, including a range of trims and finishes, allow homeowners to personalize the look of their fireplace.

In summary, the Hearth and Home Technologies Everest is more than just a fireplace; it is a sophisticated heating solution that combines aesthetics, efficiency, and technology. With its powerful heating capabilities, advanced features, and flexibility in design, the Everest elevates the concept of home comfort to new heights, making it an excellent choice for discerning homeowners.