9Chase Installations

A. Construct the Chase

Gas line holes and other openings should be caulked with

A chase is a vertical boxlike structure built to enclose the

high temperature caulk or stuffed with unfaced fiberglass

insulation. If the fireplace is being installed on a cement

fireplace and/or its vent system. Vertical chimneys that

slab, we recommend that in cold climates, a sheet of

run on the outside of a building must be installed inside a

plywood or other raised platform be placed underneath to

chase.

prevent conducting cold up into the room.

Construction of the chase may vary with the type of build-

Three examples of chase applications are shown in Fig-

ing. These instructions are not substitutes for the require-

ure 9.2.

 

 

 

 

 

ments of local building codes. Local building codes MUST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be checked.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Chimney offset through exterior wall and

A chase should be constructed in the manner of all

 

 

 

enclosed in chase.

 

 

 

 

 

outside walls of the home to prevent cold air drafting

 

 

 

 

 

 

 

 

2. Chase constructed on roof.

 

 

 

 

 

problems. The chase should not break the outside build-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ing envelope in any manner. All outer walls need to be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

insulated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Building codes require false ceiling and ceiling firestops

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

at each floor of the chase or every 10 ft (3.05 m) of clear

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

space to control spread of fire.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Walls, ceiling, base plate and cantilever floor at the first

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

level of the chase should be insulated. See Figure 9.1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vapor and air infiltration barriers should be installed in the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

chase as per regional codes for the rest of the home. Ad-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ditionally, Hearth & Home Technologies recommends that

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the inside surfaces be sheet rocked and taped (or the use

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of an equivalent method) for maximum air tightness.

1

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

Round Termination Cap

 

Figure 9.2

Chase Constructions

 

 

 

Metal Chase Top

 

 

 

 

Ceiling

 

Warning! You must install false ceilings and ceiling

 

Firestop

 

firestops at each floor of the chase or every 10 ft (3.05 m)

 

 

 

to control spread of fire.

 

 

 

Warning! Risk of Fire! Do not seal area between fire

 

 

 

stop opening and chimney pipe. Restricting air flow around

 

 

 

chimney may cause fire.

 

False Ceiling

 

Warning! Risk of Fire! You must maintain a minimum

 

 

 

2 in. (51 mm) air space clearance to insulation and other

 

Attic

 

materials surrounding the chimney system.

Tabs

Insulation

 

• Insulation and other materials must be firmly secured to

Shield

 

 

 

prevent accidental contact with chimney system.

 

Ceiling

Insulation in the

 

• The chase must be properly blocked to prevent blown

 

Firestop

 

outside walls

insulation or other combustibles from entering and

Insulation

Insulation

of the chase

 

making contact with fireplace or chimney.

False Ceiling

False Ceiling

 

• Failure to prevent contact between insulation or other

 

Chimney

 

materials and chimney system may cause overheating

 

 

 

and fire.

 

Figure 9.1

Chase Assembly

 

 

 

32

Heatilator • FL92 Multi-Sided Woodburning Fireplace • 34955 • Rev AA 7/12

Page 32
Image 32
Hearth and Home Technologies FL92 MULTI-SIDED owner manual Chase Installations, Construct the Chase

FL92 MULTI-SIDED specifications

The Hearth and Home Technologies FL92 MULTI-SIDED fireplace stands out as a versatile and stylish option for modern living spaces. This innovative fireplace offers impressive functionality, blending warmth and ambiance with contemporary design. One of its main features is its multi-sided configuration, which allows for a unique installation that can transform any room. With options for both three-sided and two-sided designs, it facilitates an open, spacious feel and encourages a flow of light and warmth across multiple areas.

The FL92 MULTI-SIDED is built with advanced technology that enhances both performance and user experience. It features a powerful heat exchanger system that efficiently distributes warmth throughout the room, making it an excellent choice for heating larger areas. Additionally, its adaptive ignition ensures an efficient burn, minimizing energy consumption while maximizing output. This eco-friendly approach not only benefits homeowners but also the environment by reducing emissions.

The design of the FL92 MULTI-SIDED is equally impressive. It boasts a sleek, contemporary appearance that can seamlessly integrate into various interior styles, from modern to rustic. The expansive glass viewing area provides an unobstructed view of the mesmerizing flames, creating a focal point in any setting. Customizable trim options and finishes allow homeowners to tailor the fireplace to their specific aesthetic preferences, ensuring it complements their decor beautifully.

One of the standout characteristics of the FL92 MULTI-SIDED is its ease of operation. The fireplace can be controlled via a remote, offering convenience for users when managing heat and flame height. Moreover, it includes a self-diagnostic control system that aids in monitoring the fireplace's performance, ensuring safety and efficiency over time.

Whether used as a primary heating source or a visual centerpiece, the Hearth and Home Technologies FL92 MULTI-SIDED fireplace offers an impressive combination of style, functionality, and innovative technology. Its multi-sided design, efficient heating capabilities, eco-friendly operation, and aesthetic versatility make it an exceptional choice for homeowners looking to enhance their living spaces with the warmth and charm of a contemporary fireplace.