2. Continue Adding Vent Components

Refer to Cinch Pipe and Termination Cap installation in- structions.

Continue adding vent components, locking each succeed- ing component into place.

Ensure that each succeeding vent component is secure- ly fitted and locked into the preceding component in the vent system. Securing pipe sections with a maximum of two screws is recommended.

90° elbows may be installed and rotated to any point around the preceding component’s vertical axis. If an el- bow does not end up in a locked position with the pre- ceding component, attach with a minimum of two (2) sheet metal screws.

3.Install Support Brackets

Refer to Cinch Pipe and Termination Cap installation in- structions.

4. Install Firestops

For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes.

NOTE: Model DVP-TRAP does not need an exterior firestop on an exterior combustible wall. The firestop is built into the cap.

To install firestops for horizontal runs that pass through either interior or exterior walls:

• Cut a 10” x 12” (254mm X 305mm) hole through the wall.

NOTE: The center of the hole is one (1) inch (25.4mm) above the center of the horizontal vent pipe.

Position the firestops on both sides of the hole previ- ously cut and secure the firestops with nails or screws.

The heat shields of the firestops MUST BE placed to- wards the top of the hole.

Continue the vent run through the firestops.

NOTE: There must be NO INSULATION or other combustibles inside the framed firestop opening.

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102mm to 184mm) thick. If wall thickness is less than 4 in. (102mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184mm) a DVP-HSM-B will be required.

HEAT

SHIELD3 in. TOP

CLEARANCE

HEAT

SHIELD

1 in. CLEARANCE

WALLBOTTOM & SIDES SHIELD

FIRESTOP

WALL

For Vertical Runs - One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes.

To install firestops for vertical runs that pass through ceilings:

Position a plumb bob directly over the center of the verti- cal vent component.

Mark the ceiling to establish the centerpoint of the vent.

Drill a hole or drive a nail through this centerpoint.

Check the floor above for any obstructions, such as wir- ing or plumbing runs.

Reposition the fireplace and vent system, if necessary, to accommodate the ceiling joists and/or obstructions.

Cut an 10-inch X 10-inch (254mm x 254mm) hole through the ceiling, using the centerpoint previously marked.

Frame the hole with framing lumber the same size as the ceiling joists.

 

10" (254mm)

10" (254mm)

 

10"

 

 

 

INTERIOR

 

 

WALL SHIELD

 

 

 

CHIMNEY

 

 

HOLE

 

12"

 

 

NEW

EXISTING CEILING

 

JOISTS

 

FRAMING

 

 

 

MEMBERS

 

 

CEILING

 

 

Figure 23. 10" x 12" Hole and Vent Pipe

 

 

Figure 25 Hole & New Framing Members

26

Heat & Glo • PIER-HVB-IPI, ST-HVB-IPI2006-901 Rev. C • 12/07

 

Page 26
Image 26
Hearth and Home Technologies Pier-HVB-IPI, ST-HVB-IPI owner manual Continue Adding Vent Components, Install Support Brackets

Pier-HVB-IPI, ST-HVB-IPI specifications

Hearth and Home Technologies has made significant strides in the fireplace and heating solutions market with their innovative products, including the ST-HVB-IPI and Pier-HVB-IPI models. These high-efficiency fireplaces promise to bring both functionality and aesthetic appeal to any living space.

The ST-HVB-IPI is designed as a versatile, direct vent gas fireplace that maximizes heat output while maintaining an elegant appearance. One of its standout features is the IntelliFire® Ignition System, which ensures safe and reliable ignition while conserving energy. This system allows for easy operation, making it user-friendly for anyone looking to enjoy a cozy fire with minimal hassle.

In terms of design, the ST-HVB-IPI offers a modern, clean aesthetic that can fit seamlessly into various home styles. With customizable options for fronts, media, and finishes, users can personalize their fireplace to match their décor preferences. Additionally, the large viewing area provides an unobstructed view of the flames, enhancing the ambiance of any room.

The Pier-HVB-IPI, on the other hand, serves as a striking centerpiece in spaces with its unique multi-sided design. This model also utilizes the IntelliFire® Ignition System and is engineered for high thermal efficiency, making it a great option for homeowners looking to optimize their heating without sacrificing style. The Pier model allows for installation in various configurations, promoting versatility in home design.

Both models boast exceptional engineering with a focus on performance. They are equipped with a high-efficiency heat exchanger that maximizes heat output while reducing energy consumption. This feature not only keeps living spaces warm but also enhances overall energy efficiency, which is a growing concern among eco-conscious consumers.

Safety is another key priority for Hearth and Home Technologies. Both fireplaces come designed with safety features such as a safety barrier and optional glass doors that help keep children and pets safe while ensuring the fire remains contained.

In conclusion, the ST-HVB-IPI and Pier-HVB-IPI by Hearth and Home Technologies stand at the intersection of modern design and innovative technology. Offering customizable aesthetics, advanced ignition systems, and enhanced safety and efficiency features, these models are exemplary choices for homeowners seeking to elevate their living environments with elegance and warmth.