4Maintaining and Servicing Your Fireplace

Fireplace Maintenance

Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace maintenance task.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACE.

Replacing old ember material

Frequency: Once annually, during the checkup.

By: Qualified service technician.

Task: Brush away loose ember material near the burner. Replace old ember material with new dime-size and shape pieces of Golden Ember (GE-93) and Glowing Ember (050- 721). New ember material should be placed alternately on top of the burner - a layer of Golden Ember, a layer of Glowing Ember, and so on. Save the remaining ember material and repeat this procedure at your next servicing. For more information, see Placing Ember Material.

Cleaning Burner and Controls Frequency: Once annually. By: Qualified service technician.

Task: Brush or vacuum the control compartment, fireplace logs and burner areas surrounding the logs.

Cleaning Flame Sensor Rod (IPI Systems)

Frequency: Periodically.

By: Qualified service technician.

Task: Make a visual check of the straight flame sensor rod. Use emery cloth to carefully remove any existing white film or deposits.

Checking Flame Patterns, Flame Height

Frequency: Periodically.

By: Qualified service technician/Home owner.

Task: Make a visual check of your fireplace’s flame patterns. Make sure the flames are steady - not lifting or floating. See Figure 48. The flame sensor (IPI) tips should be covered with flame. See Figure 32.

MAKE SURE THE FLAMES

ARE STEADY—NOT

LIFTING OR FLOATING.

Figure 48. Burner Flame Patterns

Checking Vent System

Frequency: Before initial use and at least annually thereafter, more frequently if possible.

By: Qualified service technician/Home owner.

Task: Inspect the external vent cap on a regular basis to ensure that no debris is interfering with the flow of air. Inspect entire vent system for proper function.

Cleaning Glass Door

Frequency: After the first 3 to 4 hours of use. As neces- sary after initial cleaning.

By: Home owner.

Task: Remove and clean glass after the first 3 to 4 hours of use. After the initial cleaning, clean as necessary, particu- larly after adding new ember (flame colorant) material. Film deposits on the inside of the glass door should be cleaned off using a household glass cleaner. NOTE: DO NOT handle or attempt to clean the door when it is hot and DO NOT use abrasive cleaners.

41

Page 41
Image 41
Hearth and Home Technologies LCOR-HVB-IPI, RCOR-HVB-IPI owner manual Fireplace Maintenance

RCOR-HVB-IPI, LCOR-HVB-IPI specifications

Hearth and Home Technologies has established itself as a leading name in the hearth and home industry, providing innovative and high-performance heating solutions. Two standout products from their extensive lineup are the LCOR-HVB-IPI and RCOR-HVB-IPI. Both units exemplify the company's commitment to quality craftsmanship, modern technology, and energy efficiency.

The LCOR-HVB-IPI, an attractive linear model, is designed to bring elegance and warmth to any living space. Its sleek design boasts a contemporary aesthetic, making it a perfect centerpiece for modern homes. One of the main features of the LCOR-HVB-IPI is its impressive heat output capability, ensuring that even the coldest days are comfortably warm. The unit can be controlled via a remote, allowing users to set the desired temperature with ease.

In terms of technology, the LCOR-HVB-IPI employs a sophisticated direct vent system which ensures safe and efficient combustion. This feature not only enhances the overall performance of the unit but also provides peace of mind, knowing that harmful gases are vented outside effectively. The unit is equipped with an IPI (Intermittent Pilot Ignition) system, which allows for energy savings by eliminating the need for a constantly burning pilot light.

On the other hand, the RCOR-HVB-IPI shares many of the same features but is crafted as a traditional-style fireplace. With its charming design, the RCOR-HVB-IPI integrates seamlessly into classic home decor while providing the latest in heating technology. This model also prioritizes energy efficiency, utilizing a similar direct vent system for safe operation and optimized heating.

Both models feature glass doors that provide an unobstructed view of the flames, adding to the ambience of the room. User-friendly controls make it simple to adjust settings, and the option to customize the fire media further enhances the aesthetic appeal.

Additionally, both the LCOR-HVB-IPI and RCOR-HVB-IPI are designed with environmental considerations in mind. Their high-efficiency ratings ensure that they meet or exceed industry standards for emissions, contributing to cleaner indoor air quality.

In summary, Hearth and Home Technologies’ LCOR-HVB-IPI and RCOR-HVB-IPI models are perfect examples of how modern innovation can blend with classic designs to create efficient, stylish heating solutions. Whether you're looking for a contemporary linear model or a traditional fireplace design, these units offer the best of both worlds, ensuring that your home remains warm and inviting throughout the year.