RHW-41/RHW-47 INSTALLATION INSTRUCTIONS

3. Sidewalls/Surrounds

Adjacent combustible side walls must be located a minimum of 12 in. from the fireplace opening. See Figure 6. If you are using a decorative surround constructed of combustible material, it must be located within the shaded area defined in Figure 6. Short stub walls are also acceptable if they are contained within the shaded area.

Figure 6 - Sidewalls and Surrounds

E. CHIMNEY REQUIREMENTS

When planning your fireplace location, the chimney construction and necessary clearances must be considered. The fireplace system and chimney components have been tested to provide flexibility in construction. The following figures are the minimum distances from the base of the fireplace.

1.

Minimum overall straight height

13 ft

2.

Minimum height with offset/return

14.5 ft

3.

Maximum height

90 ft

4.

Maximum chimney length between an offset and return

12 ft

5.

Maximum distance between chimney stabilizers

35 ft

6.

Double offset/return minimum height

20 ft

7.

Maximum unsupported chimney length between the offset and return

6 ft

8.

Maximum straight unsupported chimney height above the fireplace

35 ft

12

26022 Rev i

08/04

Page 12
Image 12
Hearth and Home Technologies RHW-47, RHW-41 operating instructions Chimney Requirements, Sidewalls/Surrounds