B. Clearances

WARNING

Fire Risk

• Comply with all minimum clearances to combustibles as specifi ed.

Failure to comply may cause fi re.

Storm Collar

Roof Flashing

2 in. min.

(51 mm)

(attic)

2 in. (51 mm) min.

Firestop Spacer

2 in. (51 mm) min.

2 in. (51 mm) min.

Attic

Insulation

Shield

Firestop Spacer

(ceiling)

2 in. (51 mm) min.

Offset/Return with hanger straps

(ceiling)

2 in. (51 mm) min.

Must have 2 in. (51 mm)

minimum clearance

to header

0 in. to level of standoffs

0 in.

1/2 in. (13 mm) to side of appliance

to floor

Figure 3.2 Clearances to Combustible Materials

10

Heatilator • ST42A • 35038 Rev G • 02/05

Page 10
Image 10