Hearth and Home Technologies ST42A owner manual Install the Termination Cap

Models: ST42A

1 44
Download 44 pages 28.11 Kb
Page 22
Image 22

C. Install the Termination Cap

Install the chimney sections up through the chase enclosure. When using a TR11 Round Termination Cap, the uppermost top section of pipe must extend 6 in. (152 mm) above the top of the fl ashing collar to allow installation of the storm collar and termination cap. See Figure 6.5.

For installations utilizing a TR11T Round Telescoping Termination Cap, the uppermost chimney section must be below the top of the chase top, but not more than 14 -1/2 in. (368 mm) below the top of the chase top. Minimum overlap of chimney and termination cap must be 1-1/2 in. (38 mm). See Figure 6.6.

For installations utilizing an ST1175 Square Termination Cap the last chimney section must not be more than 4-1/2 in. (114 mm) below the chase top. See Figure 6.7.

For installations utilizing an TCT1175 Terra Cotta Cap the last chimney section must be between 7 in. (178 mm) below the chase top and 2 in. (51 mm) above. See Figure 6.8.

For chase installations you can use a TR11 Round Termination Cap, a TR11T Round Telescoping Termination Cap, an ST1175 or a TCT1175 Terra Cotta Termination Cap.

Install the termination cap following the instructions provided with it.

Note: To protect against the effect of corrosion on those parts exposed to the weather, the termination cap can be painted with a rust-resistant paint.

WARNING

Fire Risk

The minimum overlap of cap to pipe MUST be met or chimney may separate from cap.

Separation allows sparks, heat and embers to escape.

 

 

 

 

 

 

Flashing Collar

Cap Standoff

 

 

 

 

2 in. (51 mm) min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-1/2 in.

1-1/2 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(38 mm) min.

 

 

 

 

 

(114 mm)

overlap

Top of Pipe

 

 

 

 

 

 

max.

Figure 6.7 Installing an ST1175 Square Termination Cap

Minimum 1-1/2 in. (38 mm) overlap of cap over pipe

Storm Collar

2 in. (51 mm) min.

6 in. (152mm) min.

 

 

 

 

 

 

 

Flashing Collar

 

 

 

 

2 in. (51 mm) min. collar

 

 

1-1/2 in. (38 mm) min. overlap

{

Top of Pipe

The last section of pipe must stop between the distances given below.

2 in. (51 mm) above top of the chase.

7 in. (178 mm) below top

of the chase.

Figure 6.5 Installing a TR11 Round Termination Cap

 

 

 

Storm Collar

Flashing Collar

2 in. (51 mm) min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14-1/2 in. (368mm) max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of Pipe

 

 

 

1-1/2 in. (38 mm) min.

 

 

 

 

 

 

overlap

Figure 6.6 Installing a TR11T Round Telescoping Termination Cap

Figure 6.8 Installing a TCT1175 Terra Cotta Cap

22

Heatilator • ST42A • 35038 Rev G • 02/05

Page 22
Image 22
Hearth and Home Technologies ST42A owner manual Install the Termination Cap, Installing an ST1175 Square Termination Cap

ST42A specifications

Hearth and Home Technologies ST42A is a highly regarded product in the realm of home heating, known for its excellent combination of functionality, efficiency, and aesthetic appeal. This stylish gas fireplace offers the perfect blend of modern design and superior technology, making it an ideal choice for homeowners seeking both comfort and elegance.

One of the main features of the ST42A is its remarkable heating capacity. With a BTU output ranging from 26,000 to 36,000, it efficiently warms spaces, making it suitable for medium to large living areas. This gas fireplace is designed to deliver heat effectively while maximizing energy efficiency, allowing users to enjoy warmth without incurring excessive energy costs.

The ST42A comes equipped with an advanced electronic ignition system, ensuring reliable startup and operation. This system not only adds convenience but also enhances safety, as it minimizes the risk of gas leaks. The fireplace is designed to operate on natural gas or propane, offering flexibility to homeowners based on their fuel availability and preferences.

In terms of design, the ST42A boasts a contemporary look that fits seamlessly into a variety of interior styles. Its large viewing area, framed by a stylish surround, allows for an impressive flame presentation that serves as a focal point in any room. The variable flame height adjustment feature allows users to customize the ambiance and comfort level, further enhancing the overall experience.

One of the standout technologies in the ST42A is its unique heat distribution system. This feature ensures that warmth is circulated throughout the room, rather than being concentrated in one area, promoting an even temperature distribution. Additionally, the fireplace is equipped with optional blower kits that can enhance air circulation, further improving the efficiency of heat delivery.

Maintenance is another significant consideration with any heating appliance, and the ST42A simplifies this with accessible components and easy cleaning features. The ceramic glass front is designed to resist soot buildup, ensuring a clear view of the flames and reducing the need for frequent upkeep.

Overall, the Hearth and Home Technologies ST42A stands out as a premium choice for those looking to add warmth and style to their home. With its powerful heating capabilities, advanced technologies, and elegant design, it represents an investment in both comfort and aesthetic enhancement for any living space.