Installation Instructions

TM

Installation Instructions

Models:

TR342, TR344, TV342

Round Termination Cap and

Storm Collar

These chimney termination caps have been tested for use with specifi c Hearth & Home Technologies inc. fi replaces and are UL listed as fi replace parts. Refer to the installation instructions supplied with the fi replace for the correct accessories to be used. Check with your local building code agency before you begin installation to ensure compliance with local codes, including the need for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need clarifi cation of any of the instructions contained here, contact the Heatilator Technical Services Dept., Hearth & Home Technologies Inc., phone 1-800-927-6841 or 1-888-427-3973.

Note: An arrow (￿) found in the text signifi es change in content.

CAUTION

Sharp Edges

Wear protective gloves and safety glasses during installation.

Description

Qty

Termination Cap

1

 

 

Storm Collar

1

Fastener Package

1

32-3/8 in.

(822 mm)

15-3/4 in.

34-3/8 in.(400 mm)

(873 mm)

TR342

TR344

TV342

32in.

(813 mm)

34-1/4 in.

(870 mm)

￿

Note: The chimney must extend at least 3 ft (.91 m) above the highest point where it passes through the roof and at least 2 ft (.61 m) above any portion of the building within 10 ft (3.05 m). These minimum distances comply with national code construction requirements but do not guarantee smoke free operation.