TM
Installation Instructions
Models:
TR342, TR344, TV342
Round Termination Cap and
Storm Collar
These chimney termination caps have been tested for use with specifi c Hearth & Home Technologies inc. fi replaces and are UL listed as fi replace parts. Refer to the installation instructions supplied with the fi replace for the correct accessories to be used. Check with your local building code agency before you begin installation to ensure compliance with local codes, including the need for permits and
Note: An arrow () found in the text signifi es change in content.
CAUTION
Sharp Edges
•Wear protective gloves and safety glasses during installation.
Description | Qty |
Termination Cap | 1 |
|
|
Storm Collar | 1 |
Fastener Package | 1 |
(822 mm)
(873 mm)
TR342 | TR344 | TV342 |
32in.
(813 mm)
(870 mm)
Note: The chimney must extend at least 3 ft (.91 m) above the highest point where it passes through the roof and at least 2 ft (.61 m) above any portion of the building within 10 ft (3.05 m). These minimum distances comply with national code construction requirements but do not guarantee smoke free operation.
Hearth & Home Technologies Inc. • TR342/TR344 Term Cap • 31445 Rev H • 03/06 | 1 |