INSTALLATION OF DUCT TERMINATION KIT
IMPORTANT NOTES:•Any field supplied grille must have fixed louvers that cannot be closed.
•Installer must determine if any field supplied hardware such as wall plugs or anchors are required to complete the installation based on wall construction. Survey the installation area before you begin.
•The Sheet Metal Collar of the Duct Termination Kit must be mounted in the wall of the adjoining room opposite the room where the Main Duct Kit is attached to the PTAC Wall Sleeve.
1. Cut a hole in the wall of the adjoining room such that the hole is centered on the Duct Extension that is currently in the wall of the opposite room.
2.Insert the Sheet Metal Collar into the wall so that the flanges will mount flush to the wall after the collar is pushed all the way into the wall. While pushing the collar into the wall, make sure the Extension Duct is inside the collar. Use four No.8 screws provided to attach metal collar to wall.
3.Center the Metal Grille over the Sheet Metal Collar and use two #8 screws (provided) to attach the grille to the metal collar.