Installation
Installation
Remove packing sheet from the back of the sleeve, and packing corner and blue tape from the air condi- tioner.
Installationrequirements
If you use an existing wall sleeve, you should mea-
sure its dimensions.
Install the new air conditioner according to these instal- lation instructions to achieve the best performance.
All wall sleeves used to mount the new air conditioner must be in good structural condition and have a rear grille to securely attach the new air conditioner. (FIG. 1)
With the HCI sleeve(optionally supplied with your unit), you can maintain the best performance of the new air conditioner. (FIG. 2)
(499 mm)24-21/32"
(626 mm)
(366 mm)
Air Conditioner | 18"(458 mm) | FIG. 1 |
INSTALLATION HARDWARE
1 |
| 2 |
| 4 | |
|
| |
|
| 2 Size options |
| 7 | 5 |
|
|
8 | 3 |
|
| 6 |
|
| 2 Size options |
|
ITEM | NAME OF PARTS | Q'TY |
1 | PLASTIC GRILLE | 1 |
2 | HORIZONTAL INSULATION STRIPS | 2 |
3 | AROUND INSULATION STRIPS | 2 |
4 | SUPPORT BLOCK | 2 |
5 | BAFFLE | 1 |
6 | TRIM FRAME | 2 |
7 | SHIM | 2 |
8 | PLASTIC NUTS AND WASHER SCREWS | 4 |
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and
Expanded
aluminum metal grille
LGE Wall Sleeve
(656 mm)
(394 mm)
(425 mm)
FIG. 2
sharp edges that may be exposed:
• Air conditioners covered in this manual pose an |
excessive weight hazard. Two or more people are |
needed to move and install the unit. |
To prevent injury or strain, use proper lifting and |
carrying techniques when moving unit. |
• Carefully inspect location where air conditioner will |
be installed. Be sure it will support the weight of the |
unit over an extended period of time. |
• Handle air conditioner with care. Wear protective |
ELECTRICAL SERVICE
Check your available electrical service. The power supply available must be the same as that shown on the unit nameplate (found on left side of cabinet).
All models are equipped with a
gloves whenever lifting or carrying the unit. AVOID |
the sharp metal fins of front and rear coils. |
• Make sure air conditioner does not fall during instal- |
lation. |
REQUIRED TOOLS:
• Tight Fitting gloves | • | |
• Standard screwdriver | wrench or adjustable | |
wrench | ||
• Phillips screwdriver | ||
• | ||
• Pliers | ||
ratchet | ||
• Sharp knife | • Tape measure | |
| • Electric drill | |
| • |
Service Manual 7