Disassembly Instructions

10. POWER CORD

1.Remove the control box. (Refer to section 3)

2.Unfold the control box. (Refer to section 9)

3.Disconnect the grounding screw from the control box.

4.Disconnect 2 receptacles.

5.Remove a screw which fastens the clip cord.

6.Pull the power cord. (See Fig. 36)

7.Re-install the component by referring to the

removal procedure, above.

(Use only one ground-marked hole for ground connection.)

8.If the supply cord of this appliance is damaged, it must be replaced by the special cord.

(The special cord means the cord which has the same specification marked on the supply cord fit- ted to the unit.)

Cool

 

 

Energy

 

 

Saver

 

 

Fan

 

F1

 

 

F2LOW

 

 

F3 MED

 

Timer

HIGH

MODE

'F

TIMER

TEMP

 

FAN

 

 

 

 

SPEED

 

 

POWER

FIG. 36

11. THERMOSTAT

1.Remove the control box. (Refer to section 3)

2.Unfold the control box. (Refer to section 9)

3.Disconnect the theristor terminals from main P.W.B assembly.

4.Remove the thermostat. (See Fig. 37)

5.Re-install the components by referring to the removal procedure, above.

Cool

 

 

Energy

 

 

Saver

 

 

Fan

 

F1

 

 

F2LOW

 

 

F3 MED

 

Timer

HIGH

 

'F

 

 

TEMP

 

 

FAN

 

 

SPEED

 

 

POWER

FIG. 37

20Room Air Conditioner

Page 20
Image 20
Heat Controller BGE-123A, BGE-103A service manual Power Cord, Thermostat