Operating Instructions
ForcedOperation
Operation procedures when the remote control can't be used. Press the tact switch (Forced operation) for 2 seconds.
If you want to stop operation, press again the tact switch.
In case the power comes on again after power failure on the Forced Operation mode, the operating conditions are automatically set as follows:
During Forced Operation, the initial mode continues.
Forced operation (Tact switch)
| Cooling Model | Heat pump Model | |
|
|
| |
| Room Temp. ≥ set | Room Temp. < set | |
|
| ||
Operating mode | Cooling | Cooling | Heating |
|
|
|
|
Indoor FAN Speed | High | set available | set available |
|
|
|
|
Setting Temperature | 22°C | set available | set available |
|
|
|
|
Auto RestartFunction
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions.
TipsforFiltersignLED
1Filter sign lamp (LED) is ON.
2If LED indicating filter sign lamp is ON, clean the filter.
3After cleaning the filter, press the Timer button and button of wired remote controller at the same time for 3 sec. Then filter sign LED is OFF.
PLASMAPurificationOperation
AUTO SWING | OPERATION | SET TEMP | FAN SPEED | SUB FUNCTION | |||
|
|
| Room Temp | HI | AUTO | Heater | Preheat |
|
|
|
| ||||
|
|
|
| MED | JET | Defrost | Humidify |
|
|
|
| LO |
| Filter | Out door |
|
|
| Time | ZONE |
| 1 2 3 4 | |
Timer | Operation unit | Program set |
|
|
|
| |
On Off |
|
|
|
|
|
|
|
Set no. Time | 01 | 03 05 07 | 09 11 13 | 15 17 | 19 | 21 | 23 |
Timer Cancel 2ndF
Program Week Holiday
Plasma
Set/Clr
Hour Min
RESET
1 Press the On/Off button. The unit will respond with a beep.
2 Open the door on the remote control. Press the
Plasma
PLASMA air purifying operation ON/OFF button. Operation will start when the button is pressed and stop when the button is pressed again.
3 Set the fan speed again with door of the remote control closed. You can select the fan speed in four
mode is shifted.
22Cassette- Type Air Conditioner