Additional features

Auto clean

1.

Whenever you press the AUTO CLEAN button, Auto Clean Function will be selected

AUTO CLEAN

or cancelled.

Auto Clean function works before and after cooling or dehumidification mode. For

2.

 

details, refer to the below points.

3.

When the unit is started after selecting Auto Clean ,the Cool Start function operates

 

and indoor Fan is started after 20 seconds.

4.

When you press Start/Stop button to turn off the unit after the you have selected

 

Auto Clean function, the air-conditioner circulates the indoor air in the Auto Clean

 

mode with no more Cooling or Dehumidification operation. It lasts for 30 minutes.

5.

If you press the AUTO CLEAN button again during the product operation , Auto

 

Clean function will be cancelled.

NOTICE

During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy Dehumidification Operation can be removed.

During Auto Clean function, only Start/Stop button, Plasma button and AUTO CLEAN button are available.

Forced Operation

The operation will be started operation if the power button is pressed without remote controller. If you want to stop operation, re-press the button.

ON/OFF

button

 

Cooling Model

 

Heat pump Model

 

 

 

 

 

 

Room Temp. 24°C(76°F)

21°C(70°F) Room Temp. < 24°C(76°F)

Room Temp. < 21°C(70°F)

 

 

 

 

 

 

 

Operating mode

Cooling

Cooling

Healthy Dehumidification

Heating

Indoor FAN Speed

High

High

High

High

 

 

 

 

 

Setting Temperature

22°C(72°F)

22°C(72°F)

23°C(74°F)

24°C(76°F)

 

 

 

 

 