Heat Controller HDG60, HDG48 Unit Dimensions, Dimensions Dimensional Data, HDG Series Air Handler

Models: HDG HDG36 HDG42 HDG24 HDG30 HDG60 HDG48

1 27
Download 27 pages 51.87 Kb
Page 8
Image 8
3.1 Unit Dimensions

HDG Series Air Handler

INSTALLATION INSTRUCTIONS

Heat Controller, Inc.

3.1 Unit Dimensions

ELECTRICAL CONNECTIOS

MAY EXIT TOP OR EITHER SIDE

 

7/8”,

HIGHVOLTAGELTAGECONNECTION 7/8”,

1-3/8”, 1-3/4”

KNOCK

1-23/64”, 1-23/32”DIAMETERKNOCK OUTOUTS

LOW VOLTAGE CONNECTION

BREAKER SWITCH

(FOR ELECTRIC HEATER ONLY)

NOTE: 24” CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE.

SUPPLY AIR

FLANGES ARE PROVIDED

FOR FIELD INSTALLATION

 

5

 

 

W

0

16

 

1

 

A

 

 

 

 

H

VAPOR LINE CONNECTION COPPER (SWEAT)

LIQUID LINE CONNECTION COPPER (SWEAT)

AUXILIARY DRAIN CONNCECTION 3/4”

FEMALE PIPE THREAD (NPT)

AUXILIARY DRAIN CONNECTION 3/4”

 

FEMALE PIPE THREAD (NPT)

D

 

PRIMARY DRAIN CONNCETION 3/4”

FEMALE PIPE THREAD (NPT)

Fig. 1 Dimensions

Dimensional Data

UPFLOW UNIT SHOWN;

UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT, OR LEFT AIR SUPPLY.

 

 

Dimensions

 

Unit Weight lbs. [kg]

 

Unit Height

Unit Weight

Unit Lenght

Supply Duct

 

 

Model Size

in. [mm]

in. [mm]

in. [mm]

“A” in [mm]

Net

Shipping

HDG18

41 3/8" [1050]

18 1/8" [460]

20 1/2" [520]

16" [406]

106 [48]

119 [54]

HDG 24

41 3/8" [1050]

18 1/8" [460]

20 1/2" [520]

16" [406]

106 [48]

119 [54]

HDG 30

41 3/8" [1050]

18 1/8" [460]

20 1/2" [520]

16" [406]

119 [54]

132 [60]

HDG36

46 1/2" [1180]

19 5/8" [500]

20 5/8" [550]

18" [456]

141 [64]

156 [71]

HDG42

46 1/2" [1180]

19 5/8" [500]

20 5/8" [550]

18" [456]

141 [64]

156 [71]

HDG48

54 1/2” [1385]

22” [560]

24" [610]

19 1/2” [496]

171 [78]

187 [85]

HDG60

54 1/2” [1385]

22” [560]

24" [610]

19 1/2” [496]

171 [78]

187 [85]

7

Page 8
Image 8
Heat Controller HDG60 Unit Dimensions, Dimensions Dimensional Data, HDG Series Air Handler, Installation Instructions